Code
PossIble CAuse
13
Loose belt
14
Engine or pump mounting nuts are loose.
15
Pump stiffener bracket bolt is loose
16
Loose pulley
Loose flywheel
17
18
Carbon build-up in pump
19
Belt to tight
0
Pulley misalignment
1
Air tank pressure is too high
PossIble solutIon
Check belt tension, see Adjusting belt tension under
Maintenance.
Torque pump mounting nuts to 6– 8 ft.-lbs. (8.1–10.8 Nm).
Torque engine mounting nuts to 8– 10 ft.-lbs. (10.8–13.6 Nm).
WARNING: Risk of bursting. Excessive vibration could
weaken the air tank and cause it to rupture or explode.
Mounting screws must be kept tightened.
Check bolt and tighten if required. Torque pump stiffener
bracket bolt to 10– 1 ft.-lbs. (13.6–16.3 Nm).
WARNING: Risk of bursting. Excessive vibration could
weaken the air tank and cause it to rupture or explode.
Stiffener bracket bolt must be kept tightened. Never operate
the unit unless equipped with the stiffener bracket.
Tighten pulley set screw, torque to 145–165 in.-lbs.
(16.4– 18.6 Nm).
Tighten
flywheel
(0.3– 4.4 Nm).
Contact an EMGLO factory service center or an EMGLO
authorized service center.
Check belt tension, see Adjusting belt tension under
Maintenance.
See
Motor
Pulley/flywheel
Maintenance.
Open the regulator and reduce air tank pressure to less
than 40 PSI (75.8 kPa).

screw,
torque
to
15–18
Alignment
ft.-lbs.
under

Publicidad