Technical Data; Tests And Approvals - Berner BWDVC PERM L Instrucciones Para El Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
15

Technical Data

Type: ISP
Voltage
Frequency
Rated power
Max. power
Air flow*
Negative pressure*
Air flow**
Negative pressure**
Noise level
Weight
Dimensions (l x w x h)
* at the fan
** at the hose
Max. power on vacuum cleaners with plug socket: 2000 Watt (220-240V~) / 400 Watt (120V~)
Mains connection cable on vacuum cleaners with plug socket: H05RR-F3G1,5
Mains connection cable on ASBESTOS vacuum cleaners with plug socket: H07RN-F3G1,5
16

Tests and approvals

Electro-technical tests must be carried out in accordance with the accident prevention regulations (BGV A3) and in accordance with
DIN VDE 0701 Part 1 and Part 3. These tests are required in accordance with DIN VDE 0702 at regular intervals and after repair or modifi-
cation.
The vacuum cleaners are successfully tested in accordance with IEC/EN 60335–2–69.
Old equipment contains valuable materials which are designed
for re-processing. The vacuum cleaners must not be thrown
away in the normal household waste, but should be disposed
of at a suitable proper collection system, e. g. via your communal
disposal location.
28 - en
All manuals and user guides at all-guides.com
Modell:
PERM L, PERM M-1
Volt
220-240 V~
Hertz
50/60 Hz
Watt
1200
Watt
1400
l/s
73
hPa/MG 270
l/s
42
hPa/SE
235
dB(A)
69
kg
15,5
cm
53 x 40 x 56
NOTE
Modell:
PERM H Asbest
220-240 V~
50/60 Hz
1000
1200
70
265
40
230
69
15,5
53 x 40 x 56

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bwdvc perm h asbestBwdvc perm m-1367932365900365899

Tabla de contenido