Description Of Connections; Typical Installation - Roger B70/2ML Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 142
5

Description of connections

5.1

Typical installation

3
3
8
9
It is the installer's responsibility to verify the adequacy of the cables in relation to the
devices used in the installation and their technical characteristics.
1
Power supply
Motor 1
2
Motor 2
3
4
LED Flashing light FIFTHY/24
5
Power supply 24Vdc
6
Antenna
Key selector R85/60
Key pad H85/TTD - H85/TDS
7
(connecting to H85/DEC - H85/DEC2)
H85/DEC - H85/DEC2
(connecting to control unit)
Gate open indicator
8
Power supply 24V DC 3W max
Courtesy light (Potential free contact)
9
Power supply 230 Vac (100 W max)
SUGGESTIONS: with existing installations, we recommend checking the cross section of the cables and that
the cables themselves are in good condition.
54
5
6
4
2
1
F4ES/F4S
F4ES/F4S
2
4
Recommended cable
2
double insulated cable
Cable 3x2,5 mm² (max 10
Cable 3x2,5 mm² (max 10
Cable 5x0,5 mm
(max 20 m)
2
Cable 3x0,5 mm
(max 20 m)
2
Cable 2x1 mm
(max 10 m)
2
Cable 50 Ohm RG58 (max 10 m)
Cable 3x0,5 mm
(max 20 m)
2
Cable 2x0,5 mm
(max 30 m)
2
Cable 4x0,5 mm
(max 20 m)
2
The number of conductors increases when using more than
one output contact on H85/DEC - H85/DEC2
Cable 2x0,5 mm
(max 10 m)
2
Cable 2x1 mm
(max 20 m)
2
7
3
3x4 mm² (max 30 m) *
3x4 mm² (max 30 m)

Publicidad

Tabla de contenido
loading

Tabla de contenido