Electrical Connections - Roger B70/2ML Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 142
5.2

Electrical connections

buffer batteries before performing any cleaning or maintenance operations.
Ensure that an adequate residual current circuit breaker with a 0.03 A threshold and a suitable
practices and in compliance with applicable legislation.
located inside the control panel box.
Strip the insulation from the ends of the power cable wires which will be connected to the
Measure the voltage on the primary mains power connection with a tester.
TRANSFORMER
For the Brushless automation system to function correctly, the mains
220÷230
V
A
V
A
N
L
+
-COM
in the external section to the electrical panel must be on an independent path and
separate from the connections to the command and safety devices (SELV = Safety Extra Low
Voltage).
Make sure that the mains power conductors and the accessory wires (24 V) are separated.
The cables must be double insulated, strip them near the relevant connection terminals and
lock them with clamps (not supplied).
N
L
N L
+
X-Y-Z
Z-Y-X
DESCRIPTION
Installation on AYRON motor.
Mains power supply 230 Vac ±10% 50 Hz connection.
Fuse 5x20 T1A.
Mains power supply 230 Vac ±10% 50 Hz connection. (115 Vac ± 10% 60Hz).
Installation on box.
Fuse 5x20 T1A.
Connection to ROGER brushless MOTOR 1.
Warning! If the motor rotates in the wrong direction, simply swap any two of the three
motor connectors.
Connection to ROGER brushless MOTOR 2.
Warning! If the motor rotates in the wrong direction, simply swap any two of the three
motor connectors.
55

Publicidad

Tabla de contenido
loading

Tabla de contenido