Enabled. The open (AP) or close (CH) button must be pressed continuously to operate the gate. The gate stops when
the button is released.
Gate open indicator / photocell test function and "battery saving"
The indicator is off when the gate is closed, and steadily lit during manoeuvres and when the gate is open.
If the gate is stopped in an intermediate position, the lamp extinguishes twice every 15 seconds.
Set
NB
Set to
When the gate is completely open or closed, the control unit deactivates any accessories connected to terminal SC to
reduce battery consumption.
Set to
NB
Setting deceleration MOTOR 1 during opening and closing
Setting deceleration MOTOR 2 during opening and closing
01= the gate decelerates near stops and the limit switch (if installed).
...
05= the gate decelerates long before stops and the limit switch (if installed).
Adjusting LEAF 1 position control when completely opens or closes
mechanical stop. The position of LEAF 1 is calculated by the system from the number of motor revolutions and the
motor reduction gear ratio.
Warning! Excessively low values cause the gate to reverse when it reaches the gate open stop.
Adjusting LEAF 2 position control when completely opens or closes
mechanical stop. The position of LEAF 2 is calculated by the system from the number of motor revolutions and the
motor reduction gear ratio.
Warning! Excessively low values cause the gate to reverse when it reaches the gate closed stop.
motor revolutions (
Partial opening adjustment (%)
N.B.: with double leaf swing gate installations, this parameter is set by default as the completely open position of
LEAF 1.
With single leaf swing gate installations, this parameter is set to 50% of total opening.
From 15% to 99% of total gate travel.
Type of signaling provided by COR output
STANDARD operation managed by parameter
Contact closed if the control unit is working properly.
Contact open if central locked in alarm.
Contact closed if the control unit is powered by the mains or charged battery.
(the control unit no longer accept commands).
Closed contact if none of the fault related situations 1 and 2 occurs.
Open contact if at least one of the fault related situations 1 and 2 occurs
Closed contact if the gate is not completely open.
Open contact if the gate is completely open.
Closed contact if the gate is not completely closed.
Open contact if the gate is completely closed.
Adjusting stop advance of LEAF 1 when opening
Adjusting stop advance of LEAF 2 when opening
The leaf stops against the opening stop.
A leaf stop advance of 1 to 25 motor turns before the completely open position may be set.
66
= maximum).
and
.
and
.
) or with error alert