ENglIsH
120V Max* (two 60V Max* batteries) product, it will operate
as a 60V Max* battery.
shipping Mode: When the
cap is attached to the
FLEXVOLT™ battery, the
battery is in Shipping
Mode. Strings of cells are
electrically disconnected within the pack resulting in three
batteries with a lower Watt hour (Wh) rating as compared to
one battery with a higher Watt hour rating. This increased
quantity of three batteries with the lower Watt hour rating
can exempt the pack from certain shipping regulations that
are imposed upon the higher Watt hour batteries.
The battery label indicates two Watt hour ratings (see
example). Depending on how the battery is shipped, the
appropriate Watt hour rating must be used to determine
the applicable shipping requirements. If utilizing the
shipping cap, the pack will be considered 3 batteries at
the Watt hour rating indicated for "Shipping". If shipping
without the cap or in a tool, the pack will be considered one
battery at the Watt hour rating indicated next to "Use".
Example of Use and Shipping Label Marking
USE: 120 Wh Shipping: 3 x 40 Wh
For example, Shipping Wh rating might indicate 3 x 40 Wh,
meaning 3 batteries of 40 Watt hours each. The Use Wh
rating might indicate 120 Wh (1 battery implied).
Fuel Gauge Battery Packs (Fig. B)
Some D
WALT battery packs include a fuel gauge which
e
consists of three green LED lights that indicate the level of
charge remaining in the battery pack.
The fuel gauge is an indication of approximate levels of
charge remaining in the battery pack according to the
following indicators:
To actuate the fuel gauge, press and hold the fuel gauge
button. A combination of the three green LED lights will
illuminate designating the level of charge left. When the
level of charge in the battery is below the usable limit, the
fuel gauge will not illuminate and the battery will need to
be recharged.
Fig. B
NoTE: The fuel gauge is only an indication of the charge left
on the battery pack. It does not indicate tool functionality
and is subject to variation based on product components,
temperature and end-user application.
28
75–100% charged
51–74% charged
< 50% charged
Pack needs to be charged
For more information regarding fuel gauge battery packs,
please contact your local service center.
Important Safety Instructions for All
Battery Chargers
WARNING: Read all safety warnings and all
instructions for the battery pack, charger and
power tool. Failure to follow the warnings and
instructions may result in electric shock, fire and/
or serious injury.
•
DO NOT attempt to charge the battery pack with
any chargers other than the ones in this manual.
The charger and battery pack are specifically designed to
work together.
•
These chargers are not intended for any uses other
than charging D
WALT rechargeable batteries.
e
Any other uses may result in risk of fire, electric shock
or electrocution.
Do not expose the charger to rain or snow.
•
•
Pull by the plug rather than the cord when
disconnecting the charger. This will reduce the risk of
damage to the electric plug and cord.
•
Make sure that the cord is located so that it will not
be stepped on, tripped over or otherwise subjected
to damage or stress.
•
Do not use an extension cord unless it is absolutely
necessary. Use of improper extension cord could result in
risk of fire, electric shock or electrocution.
•
When operating a charger outdoors, always provide
a dry location and use an extension cord suitable
for outdoor use. Use of a cord suitable for outdoor use
reduces the risk of electric shock.
•
An extension cord must have adequate wire size
for safety. The smaller the gauge number of the wire,
the greater the capacity of the cable, that is, 16 gauge
has more capacity than 18 gauge. An undersized cord
will cause a drop in line voltage resulting in loss of power
and overheating. When using more than one extension
to make up the total length, be sure each individual
extension contains at least the minimum wire size. The
following table shows the correct size to use depending on
cord length and nameplate ampere rating. If in doubt, use
the next heavier gauge. The lower the gauge number, the
heavier the cord.
Voltage
Total length of cord in meters (m)
(Volts)
120–127V
0–7
220–240V
0–15
Rated
Minimal cross-sectional area of the
ampere
cord in meters (mm
Range
0–6A
1.0
6–10A
1.0
10–12A
1.5
12–16A
2.5
Do not place any object on top of the charger or
•
place the charger on a soft surface that might block
7–15
15–30
30–50
15–30
30–60
60–100
)
2
1.5
1.5
2.5
1.5
2.5
4.0
1.5
2.5
4.0
4.0
Not Recommended