• DO NOT connect 240 Volt loads to the 120 Volt duplex
receptacles.
• DO NOT connect 3–phase loads to the generator.
• DO NOT connect 50 Hz loads to the generator.
• DO NOT OVERLOAD THE GENERATOR. See
"Don't Overload the Generator" on page 8.

Stopping the Engine

• Unplug all electrical loads from generator panel
receptacles. NEVER start or stop engine with electrical
devices plugged in and turned ON.
• Let engine run at no-load for several minutes to stabilize
the internal temperatures of engine and generator.
• Move rocker switch to "Off" position.
• Move the fuel valve to the "Off" position.
RECEPTACLES
This generator is equipped with the following receptacles:
120 Volt AC, 20 Amp Duplex
Receptacle
This receptacle (Figure 6) is protected against overload by
a push-to-reset circuit breaker.
Figure 6 — 120 Volt, 20 Amp Duplex Receptacle
Generac Portable Products 3250 Watt Generator
Use each receptacle to operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volts at 20 Amps (or greater).
120 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect a
3-wire cord set rated for 125 Volts AC at 30 Amps to the
plug (Figure 7).
Figure 7 — 120 Volt AC, 30 Amp, Locking Receptacle
3-Wire Cord Set
Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts (3.6 kW) of power
at 30 Amps. The outlet is protected by a push-to-reset
circuit breaker.
CAUTION!
Although this outlet is rated for
120 Volt 30 Amp (up to 3,600 watts), the generator
is only rated for 3,250 watts at 27 Amps. Powering
loads that exceed the wattage/amperage capacity of
the generator can damage it or cause serious
injuries.
7
NEMA L5-30
Neutral
120V
Hot
Ground (Green)

Publicidad