Care After Facial Treatment; Care And Maintenance Of The Beurer Salonpro System; Cleaning The Beurer Salonpro System; Replacing The Cartridge - Beurer IPL 9000+ Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63

8.6 Care after facial treatment

• Apply a soothing lotion such as aloe vera.
• Do not use exfoliators, whitening lotions or similar products for at least 24 hours, as this could irritate
the treated skin.
• For at least 48 hours after the treatment, avoid more than 15 minutes of direct exposure to the sun. If
recently treated skin is exposed to sunlight during this period, sun protection with SPF 30 or higher
must be applied.
• Do not remove hair on the treated areas using wax or tweezers.
Remember that it may take a complete hair growth cycle for hair removal to be complete.

9. Care and maintenance of the beurer SalonPro System

9.1 Cleaning the beurer SalonPro System

After each hair removal session, it is recommended that you clean your beurer SalonPro System, paying
particular attention to the light area.
IMPORTANT
Never immerse the beurer SalonPro System or any of its parts in water!
• Before cleaning, unplug the mains plug of the beurer SalonPro System.
• Use a clean, dry cloth and cleaning agent especially intended for electronic devices to gently wipe
the surface of the beurer SalonPro System, paying particular attention to the light surface.

9.2 Replacing the cartridge

The cartridge has a life cycle of up to 100.000 light pulses. When the cartridge reaches 80% of its life
cycle, the indicator lamp for „Cartridge empty" starts to slowly flash red. When 90% is reached, the
indicator lamp flashes at a faster pace. Once all the cartridge's light pulses are used up, no further light
pulses are generated. The indicator lamp for „Cartridge empty" then continuously illuminates red.
Changing to a new cartridge:
1. Switch off the device and remove the mains plug from the socket.
2. Hold the used cartridge on both sides and pull it out in one smooth motion. Do not use force. Dis-
pose of the used cartridge.
3. Unpack the new cartridge and plug it in.

10. Trouble-shooting

"My beurer SalonPro System cannot be switched on"
• Ensure that the mains cable is correctly connected to the beurer SalonPro System device.
• Ensure that the mains cable is inserted into a wall socket.
"No light pulse is emitted when I press the trigger button"
• Ensure that the device is in full contact with the skin and that the light area is pressed onto the skin
evenly and firmly. For your safety, the trigger button only activates a pulse if the light area is pressed
firmly against the skin.
• Check the indicator lamp. If the indicator lamp on the applicator is illuminated red, this indicates that
your skin colour, as measured by the skin colour sensor, is too dark for safe application. Test the
device on another part of your body or contact beurer SalonPro System Customer Services.
If the indicator lamp on the applicator is illuminated orange, this indicates that the contact with the
skin, as measured by the skin contact sensor, is insufficient. Increase the level of contact with the
skin or contact beurer SalonPro System Customer Services.
• The cartridge has a life cycle of up to 100.000 light pulses. When the cartridge reaches 80% of its life
cycle, the indicator lamp for „Cartridge empty" starts to slowly flash red. When 90% is reached, the
38

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Salonpro system ipl 9000+

Tabla de contenido