Mains Connection; Putting Into Operation - STAYER WELDING PLASMA 40 COM GE Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Warning: In environments with increased risk of electric
shock and fire, such as in the proximity of inflammable
products, explosives, height, restricted free moving
space, physical contact with conductive parts, warm
and humid environments that reduce the electrical resistance of
human skin and apparatus, observe the risk prevention in the
workplace and the national and international provisions as
pertinent.
3. Instruction for putting into operation
3.1. Positioning
The machine must be positioned in a dry, ventilated area and
with a separation of at least 15cm from any wall.
The equipment may slip when supported on surfaces having an
inclination of more than 3o, so that it shall mandatorily always be
placed on a flat and dry surface. When placing it on surfaces with
a greater slope, secure the machine with chains or belts.
3.2. Assembling
The equipment shall be assembled respecting its environmental
limits and positioning it correctly.
Mounting wheels.
PLASMA 100 TGE (fig. 6):
- Set the base 17 a the machine screws 21 and nuts 20.
- Make sure that wheels 18 (Ahead) should place them in the
front of the machine. Perform the same procedure with the
wheels rear 19 (Behind).
PLASMA 40 COM GE (fig. 7):
- Remove the rubber 22 feet
- Place front wheels 18, 17 base, position and tighten the screws
nuts 20
- And 21 perform the same procedure with the rear wheels 19.
For both models:
- Fix the base of the wheels team weld screws 21 remaining-note
ranging the spinning wheels in the front part of the machine
and fixed on the back.

3.3. Mains connection

The equipment is powered by the cable and connector provided
as standard, through a differential circuit breaker and a slow-
feature electromagnetic circuit breaker having an intensity in
accordance with the table of technical features. Any connection
must have a regulatory ground connection and comply with any
national electricity regulations.
Use without regulatory ground connection is prohibited.
In the case of a connection to a power generator, the power
requirements stated in the technical specification are to be
observed. It shall be taken into account that an equipment will
be able to operate with a generator providing less power than
the stated one, with the limitation that it is used with a lower
maximum intensity than the nominal one.
3.4. Illustrated description.
PLASMA 40 COM GE - PLASMA 100 T GE
1.
Interruptor ON/ OFF.
2.
Compressed air connection.
3.
Power supply connection.
4.
Air pressure limiter.
5.
Air pressure gauge.
6.
Output amp setting.
7.
Continuous air output switch.
ENGLISH
25
8.
Switch air: internal / external.
9.
Ampere output indicator.
10.
Ground connection.
11.
Prime arch signal connection.
12.
Connection of the torch trigger.
13.
Torch connection.
14.
Thermal pause indicator.
15.
Machine working.
16.
Machine on display.
17.
Limiting consumption (optional).
18.
Front wheels (Ahead).
19.
Rear wheels (Behind).
20.
Nuts (PLASMA 40 Com GE).
21.
Screws.
22.
Rubber legs (optional).
23.
Support machine.
24.
Limiting consumption (optional).
3.5 Limitations to environmental conditions.
The equipment shall be installed respecting its IP21 class, which
means that the equipment is protected at the most against
vertical impact of water drops and access to dangerous parts
with one finger against solid 12.5 mm ø or larger foreign bodies.
The equipment is prepared for working within a temperature
range from -15
C to 70
o
decrease in performance (duty cycle) as of ambient temperatures
above 40
C.
o

► PUTTING INTO OPERATION

1.
Position the air inlet coming 2 from the machine's
compressor (4 to 6 bar). Rear portion.
2.
Fasten grounding clamp 10 to the material you want
to cut.
3.
Connect current supply cable 3.
4.
Connect red cable conection 11.
5.
Connect thin black cable of the torch trigger a12.
6.
Connect torch a13
7.
Press ON/OFF button to proceed to start the machine.
8.
The digital panel will light up a 9.
9.
Check status of air by pushing the torch switch. If there
is no air, the indicator will turn on and the digital panel
will display code 806- Please revise the air supply and
confirm its good condition.
10.
Grip the torch and press the yellow safety pushbutton
downwards and immediately press the switch on the torch
to proceed to cutting.
11.
Buttons 8-9 (+ -) are for increasing or reducing the power
of the torch. You must press to activate.
4. Operating instructions.
4.1. Positioning and testing.
All WELDING machines of the series must be handled using
the handle which is arranged for transport. A free space of at
least 15cm must be arranged around the equipment, and free
circulation of air must be ensured for correct heat dissipation.
Before each work, good operation and correct tightening of all
external elements of the equipment shall be verified: power
supply plug, cable, housing structure and connection terminals
and switches.
►First step: INSTALLING THE COMPRESSED AIR.
The Plasma cutting equipments need air supply for working.
The Plasma shall be connected to a compressor capable
of providing about 5 bar constant pressure to the equipment.
Depending on the regularity of use, Plasma needs a larger or
smaller pressure vessels.
25
25
C, taking into account the limitation of a
o

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Plasma 100 tgePlasma multi 40

Tabla de contenido