Take special care not to allow aggressive liquids
or abrasive substances to run through the pump.
Never suspend the pump from the pressure line
or electric cable. Use the eyelet provided for this
purpose.
Protect the pump from freezing temperatures.
Take suitable measures to keep the pump away
from children.
It is prohibited to use cable systems, extension
cables, connection cables or adapters without an
earthing contact.
6. Putting into operation
It is imperative to observe the above safety
regulations when you put the pond filter into
operation.
Place the pond filter on a horizontal surface higher
than the bottom of the pool (this will reduce
excessive soiling by sludge deposits).
Submerge the pond filter slowly in order to allow
the air to escape from the filter chambers.
The pond filter draws in water from above. It is
important, therefore, for the pond filter to be
submerged entirely.
Never use the pond filter outside the water.
7. Fountain mode
There are 3 options:
Only the cascade fountain
The cascade fountain together with the water
spout connection for water spectacles
Only the water spout connection for water
spectacles
Operation only with the cascade fountain:
(see Figure 1)
When installing the pond filter in the pond, make sure
that the fountain head projects above the water
surface. If you want to use only the cascade
fountain, turn the shut-off cock (A) of the spout
connection clockwise one quarter of a rotation in
order to close it.
Operation of the cascade fountain and the water
spout connection: (see Figure 1)
Install the pond filter as described above. Additional
water spectacles can be connected to the water
spout connection with a hose of 9 mm inner diameter
or 13 mm diameter.
To open the spout connection, turn the shut-off cock
anticlockwise.
Seite 7
Operation only with the water spout connection:
(see Figure 2)
In this case you must turn the entire connection (B)
through 90°. All the water will then flow through the
spout connection and none through the fountain.
8. Maintenance
Regular inspections and servicing are
recommended in the interest of a long working
life without interruptions.
If the water has a high lime content, clean the
rotating parts in regular intervals.
If you notice any reduction in the delivery height
or delivery rate, clean the filter with luke warm
water.
Proceed as follows:
1. Take the complete filter chamber out of the pond
filter.
2. Undo the filter chamber lid.
3. Take out the BIOCELL filter and clean it with luke
warm water.
4. Re-assemble in reverse order.
9. Special accessories
Filter insert FS 4F for Aquamaster
4 BIOCELL filter inserts for cleaning the water by
natural, biological means
Filter insert FE 2K
A filter unit for the modular extension of the pond
filter as required. Extending the pond filter increases
its filter volume.
GB
Art. No.: 36.075.21
Art. No.: 36.075.20
7