System start-up / Self-teach
3.1
SYSTEM START-UP: SELF-TEACH CYCLE
When all the connections have been completed you
must run the self-teach cycle before putting the system
into service.
If you do not complete the self-teach cycle, the
automation will not work.
The self-teach procedure provides the controller with
information about the system so that it can set the following
operating parameters:
- Stroke length.
- Opening and closing times.
- Wing opening and closing direction; motor function
adjustment.
- Application type: two-wing or single-wing gate on
the basis of the motor connected up; motor function
adjustment.
!
Warning
During the self-teach cycle the
system will ignore all external signals with the exception
of those from the closing photocell. If a photocell pulse is
received during this cycle, the self-teach procedure will be
interrupted and will have to be repeated .
!
Warning
You must repeat the SELF-TEACH CYCLE: whenever
the "fast" parameter is reprogrammed; whenever the
number of powered wings is changed; after a RESET.
Note: When the letter S fl ashes on the board display this
indicates that you must run the self-teach procedure.

3.1.1 SELF-TEACH PROCEDURE

Before you start the self-teach procedure, ensure that
the gate is CLOSED and STOPPED ("Person present"
operation is enabled as described in sect. 3.1.2).
Press the YELLOW and BLUE buttons together for a few
seconds until 3 segments start to fl ash on the display to
indicate that the procedure has started (Fig. 4).
starts and is carried out as illustrated in Fig. 4.
At the end of the procedure the gate is closed and stopped
and the display switches off.
operating it with the key button or the remote control (if this
has already been programmed).
At the end of the self-teach cycle the system will operate
in the Automatic mode with the default settings (see sect.
5.1 and Tab. 2).

3.1.2 Person Present operation

Before you start the self-teach procedure it is possible to
operate the wings using the PERSON PRESENT control
without having to release the mechanical lock on the motors.
To use this control proceed as follows:
To move wing 1, press and hold down the RED button on
the unit.
To move wing 2, press and hold down the BLUE button.
To reverse the direction of travel of the wing, release and
then press the RED or BLUE button again.
The cycle
Now test the gate by
- 18 -
Self-teach
Gate closed
1 complete opening end closing manoeuvre
at reduced speed
1 complete opening end closing manoeuvre
at current speed
Gate closed
Fig. 4
yellow blue
3 "

Publicidad

Tabla de contenido