5. Limit stop flask positioning (see Fig.10)
Open manually the gate and leave approximately of 1÷3cm, depending on gate weight, between gate and
positive mechanical stop A; tighten the limit stop flask S with the grains G to press the limit stop micro.
Repeat the sequence with closing gate.
6. Manual operation (see Fig.11)
In the event of power failure or malfunction, to manually operate the gate proceed as follows:
- After inserting the customized key C, turn it anti-clockwise and pull the lever L.
- The geared motor is unlocked and the gate can be moved by hand.
- To return to the normal operating mode, close the lever L again and manually activate the gate until it is
geared.
7. Wire diagram (see Fig.12)
For the wire connections of the system and to adjust the operating modes, please refer to the Instruction
Manual of the control unit.
Please remember that the device should be earthed by means of the appropriate terminal.
CAUTION
The civil liability policy, which covers possible injuries to people or accidents caused by defects in construc-
tion, requires the system to be to existing standard and to use original Cedamatic accessories.