Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Error code list:
Error code
TIMER indicator
E1
1 blink
E2
2 blinks
E3
3 blinks
E4
4 blinks
E5/5E
5 blinks
F0
10 blinks
F1
11 blinks
F2
12 blinks
F3
13 blinks
F4
14 blinks
F6
16 blinks
F7
17 blinks
F8
18 blinks
F9
19 blinks
J3/P3
20 blinks
FA
21 blinks
J8/P8
22 blinks
J5/P5
23 blinks
J4/P4
24 blinks
H8
25 blinks
H1
26 blinks
H2
27 blinks
H5
28 blinks
H6
29 blinks
H7
30 blinks
H3
H3
31 blinks
31 blinks
H4
32 blinks
H9
33 blinks

5. Disposal

When using this air conditioner in the European countries, the follow information must be
followed:
Disposal:
Do not dispose this product as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:
A) The municipality has established collection systems, where electronic waste can be disposed of at
least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least free of charge.
C) The manufacture will take back the old appliance for disposal at least free of charge to the user.
D) As old products contain valuable resources, they can be sold to scrap metal dealers.
Wild disposal of waste in forests and landscapes endangers your health when hazardous substances
leak into the ground-water and find their way into the food chain.
TROUBLESHOOTING AND DISPOSAL
Indoor room temperature sensor fault (Ta)
Outdoor coil temperature sensor fault (Tcm or Tdef)
Indoor coil temperature sensor fault (Tem)
Indoor fan motor or DC motor feedback fault
Indoor & outdoor communication fault
Outdoor DC Fan motor fault
IPM module fault
PFC module fault
Compressor start fault
Exhaust temperature sensor fault (Td)
Outdoor room temperature sensor fault (Tao)
Over / under voltage protection
Main PCB & Inverter communication fault
Outdoor EEPROM fault
Refrigerant leakage detection
Suction temperature sensor fault (Ts)
Outdoor over current protection
Compressor high exhaust temperature protection
High pressure protection failure
Four way valve fault
Dranaige failure
Remote control communication fault
Compressor exhaust temperature is too low protection
Low voltage swithc fault
Low pressure protection
Evaporator inlet temperature sensor fault (Tiq)
Evaporator inlet temperature sensor fault (Tiq)
Evaporator outlet temperature sensor fault (Tas)
Indoor & outdoor communication line fault dislocation
51
Description

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Am2Am3