Note the instructions in your device's operating manual.
If these do not contain any instructions expressly to the
contrary, proceed as follows:
Warning
• Do not use force to connect the notebook connector.
• Missing or lost notebook connectors can be requested
via our support hotline or by visiting www.hama.
com/adapter-service. Available connectors will be
sent to you free of charge.
• Use the connector on the original power supply unit to
select the appropriate notebook connector.
• Without connecting it to the power supply unit,
determine the mechanical compatibility between the
notebook connector and the connection socket on the
terminal device.
• The connector must slide easily into the socket but
should not exhibit too much play.
Warning
• Only operate the product from a socket that has been
approved for the device. The socket must be installed
close to the product and must be easily accessible.
• Disconnect the product from the power supply using
the On/Off switch – if this is not available, unplug the
power cord from the socket.
• If using a multi-socket power strip, make sure that the
total power consumption of all connected devices does
not exceed the power strip's maximum throughput
rating.
• Connect the appropriate notebook connector to the
power supply unit's DC connection cable.
• Connect the power cord to the power supply unit and
your terminal device.
• Then connect the mains plug to a properly installed
socket.
• The terminal device can now be used and switched on /
charged.
Note
Disconnect the product from the mains after use.
5. Care and Maintenance
Note
Disconnect the product from the mains before cleaning.
• Only clean this product with a slightly damp, lint-free
cloth and do not use aggressive cleaning agents.
• Ensure that no water is able to enter the product.
6. Warranty Disclaimer
Hama GmbH & Co KG assumes no liability and provides no
warranty for damage resulting from improper installation/
mounting, improper use of the product or from failure to
observe the operating instructions and/or safety notes.
7. Technical data
Ambient temperature
Specifications in accordance with
Regulation (EU) 2019/1782
Manufacturer's name or trade
mark, commercial registration
number and address
Model identi er
Input voltage
Input AC frequency
Output voltage /
Output current /
Output power
Average active e ciency
E ciency at low load (10 %)
No-load power consumption
0° – 40° C
Hama, HRA12159,
Dresdner Str. 9,
86653 Monheim
00200003
100 – 240 V
50 / 60 Hz
15.0 V DC / 5.6 A / 84.0 W
19.0 V DC / 4.74 A / 90.1 W
88.5 %
90.1 %
0.11 W
3