Descargar Imprimir esta página

dirna Bergstrom TRP Compact Diagnosis De Averías página 20

Ocultar thumbs Ver también para TRP Compact:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

COMPACT
EN
Symptom
• The display shows E2 and the unit
goes off automatically, with the
display continuing to show error
E2 until the anomaly is repaired.
To remove from the display, press
the On/Off key once on the control
panel or remote control.
• The display shows E3 and the unit
goes off automatically, with the
display continuing to show E3 until
the anomaly is repaired. To remove
E3 from the display, press the On/
Off key once on the control panel or
remote control.
• The
display
(communications
when the unit starts up or runs. The
unit goes off automatically, with the
display continuing to show EC until
the anomaly is put right. To remove
EC from the display, press the On/
Off key once on the control panel or
remote control.
EC
shows
cable
failure)
20
• Centrifugal blower or condenser fan
blocked, in short-circuit or disconnected.
• 7.5A fuse of the centrifugal blower or the
condenser fan blown.
• Compressor or compressors defective or
broken.
• Compressor module or modules
disconnected or defective.
• Poor connection in compressor module
cables or terminals.
• Communication cable poorly connected or
disconnected from the electronic control.
• Compressor modules not compatible.
Cause
®

Publicidad

loading

Este manual también es adecuado para:

1541252