GB
KLG / KNG / SNG
Problem
C
Staples / Nails are
not fully inserted,
bend or protrude
D
Device repeatedly
misfires
E
Staples / Nails
jammed in the
guide plate
F
No staples / nails
are transported
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
**See Chapter: "Intended use" in Instruction manual part 1!
***For troubleshooting: read chapter: "Commissioning"!
****For troubleshooting: read chapter: "Maintenance"!
If necessary, contact our service staff, see last page.
II/ 10
Cause
Tappet worn or broken
Working pressure (flow pressure)
too low
Compressor output too small
Hose diameter too small
Piston sluggish because lubrication
insufficient
Working pressure (flow pressure)
too low
O-ring damaged
Hose diameter too small
Magazine (item 04) dirty
Staple / Nail strip jammed and/or
not pushed all the way forwards
Tappet worn
No staples / nails in the magazine
Tappet does not retract
Staple / Nail slider faulty
Magazine spring faulty
Remedy
Contact Schneider Druckluft
GmbH or an authorised ser-
****
vice partner.
Increase working pressure
(flow
pressure)
maximum
working
*
sure
Use different output
*
rating
Use correct hose diameter
Lubricate device well via
plug nipple (item 01)
Increase working pressure
(flow
pressure)
maximum
working
*
sure
Contact Schneider Druckluft
GmbH or an authorised ser-
****
vice partner.
Use correct hose diameter
Clean magazine
****
(blow out)
Incorrect
staples
used. Insert the correct sta-
*
ples / nails
Contact Schneider Druckluft
GmbH or an authorised ser-
****
vice partner.
Insert the correct staples /
****
nails
Increase working pressure
(flow
pressure)
maximum
working
*
sure
or contact Schneider Druck-
luft GmbH or an authorised
****
service partner.
Contact Schneider Druckluft
GmbH or an authorised ser-
****
vice partner.
Change magazine spring or
Contact Schneider Druckluft
GmbH or an authorised ser-
****
vice partner.
Observe
pres-
*
***
Observe
pres-
*
/
nails
Observe
pres-