Putting into operation
10. Check water inlet filter for cleanliness
10.1 If contaminated, remove sieve and
Check sieve for damages.
Do not operate high pressure without or with a damaged sieve.
11. Connect water hose to water inlet. The
Be careful when using hot water!
When running your high pressure cleaner with hot water of 60° C raised
temperatures occur. Do not touch the metal parts of the cleaner without
safety gloves!
42
prior to putting the machine into
operation. When inside filter is
contaminated, remove filter and follow
step 10.1.
thoroughly rinse and clean with the
rest of the parts in clear water.
cleaner may be connected to a water
mains (1-10 bar pre-pressure) with
either cold or hot water (up to 60°C).
Putting into operation
Never touch plug or live parts with moist or wet hands.
It is imperative that safety instructions be observed during use
of the machine.
12. Connect to circuit.
K 1050 TS T
230 V ~ , 9.6 A, 50 Hz
The socket must be protected with a
16A fuse on the mains side.
13. Switch on HP cleaner with opened
trigger gun (trigger pulled). Bleeding of
the machine: Pull and release trigger
of trigger gun with safety catch several
times. Start cleaning task.
14. When using the Dirtkiller make sure
that lance points downward when
starting.
15. The 1050 TS T units are equipped with a
support for the safety gun with lance
during breaks
16. Therefore operate high pressure clea-
ner in horizontal position only.