Installing Options - GE PHP960 Instrucciones De Instalación

Ocultar thumbs Ver también para PHP960:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLING OPTIONS

COOKTOP INSTALLATION WITH
A GE OR GE MONOGRAM 30"
DOWNDRAFT VENT
The installation of the downdraft vent with
this cooktop requires careful consideration.
Both the cooktop and the vent must be installed
according to each specific installation instruction.
BASE CABINET REQUIREMENTS
The combined installation will fit in a standard
24" deep base cabinet. Use a 36" or wider base
cabinet.
– The vent housing, blower and ductwork will
occupy the base cabinet.
Installation Instructions
2-3/4"
21-3/4"
Cutout
Depth 19-1/8"
Cooktop and Vent Cutout
Cooktop
Cutout
Depth
1-1/32" at Center
Front Edge
Clearance to Cutout
of Countertop
COOKTOP REQUIREMENTS
The countertop must have a deep flat surface to
accommodate the cooktop and vent. Countertops
with a rolled front edge and backsplash will not
provide the flat surface area required.
• Review the illustration to determine the countertop
surface requirements.
– All cutout clearances for this installation must
be observed.
1-3/4" Min. Cooktop Cutout to Rear
Vertical Combustible Surface
36-1/8" (SS)
36" (B,W)
34"
22-7/8" (B,W)
2-1/2" Min.
2" Min. Cutout
to Side Walls
2-1/2" to
Cutout
19-7/8"
3/4"
22-3/4" Inside
22" to Support Rail
5
1/4" Overlap
1/8" Gap
23" (SS)
Total Flat
Surface
Required
1-7/8"
3/4"
Thick
Support
Rail
Vent

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zhu36

Tabla de contenido