Application
Operation is possible in conjunction with:
- Pressurized storage heaters
Operation is not possible with:
- Low-pressure storage heaters
(displacement water heaters)
Specifications
• Max. flow:
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
• Non reversible cartridge
Note
Major pressure differences between hot and cold
water supply should be avoided.
Installation
Flush piping system prior and after installation of
faucet thoroughly!
Mount faucet on basin
See dimensional drawings on page 1.
For installation, see figs. [1], and [3].
Mount lift rod and pop-up drain, see figs. [1] and [2].
1.Insert the lift rod (A) through the mixer body .
2.Fit pop-up drain.
Ensure that flange of pop-up drain is sealed.
Connect faucet
For this purpose the supply hoses must be connected
to the angle stops (or other supply points), see figs. [1]
and [3].
The hot water supply should be connected on the left,
the cold water supply on the right side.
Avoid cross connection. The cartridge is not
reversible.
5.7 L/min or 1.5 gpm/60 psi
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
hot - LH
cold - RH
English
Open angle stops and check faucet for correct
function, see fig. [4].
Lift lever
Press lever down
Move lever to right
Move lever to left
Check connections for leakage.
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease.
Shut off the hot and cold water supply!
I. Replacing the cartridge, see fig. [5].
1. Remove plug (B).
2. Remove set screw (C) and detach lever (D).
3. Pull off cap (E).
4. Turn out screwing (F) with key 27mm.
5. Change complete cartridge (G).
Assemble in reverse order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the
grooves and the locating pins at the base of the
cartridge slot into the apertures on the housing.
Screw in and tighten screwing (F).
II. Flow regulator, see page 2.
Unscrew and clean flow regulator (13 351).
Assemble in reverse order.
Replacement parts, see page 2 ( * = special
accessories).
Care
Instructions for care of this single lever faucet will be
found in the Limited Warranty supplement.
= open (water flow)
= closed (off)
= cold water
= hot water