ENGLISH
(Original instructions)
1
Compressor air output per
minute
2
Nailing frequency
3
Adjuster
4
Shallow
5
Deep
6
Too deep
7
Flush
8
Too shallow
SPECIFICATIONS
Model
Air pressure
Nail length
Nail capacity
Min. hose diameter
Pneumatic tool oil
Dimensions (L x H x W)
Net weight
• Due to our continuing program of research and devel-
opment, the specifications herein are subject to change
without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
Intended use
The tool is intended for the preliminary interior work such
as fixing floor joists or common rafters and framing work
in 2" x 4" housing.
Pneumatic nailer/stapler safety warnings
WARNING: Read all safety warnings and all instruc-
tions. Failure to follow the warnings and instructions may
result in serious injury, electric shock and/or fire.
Save all warnings and instructions for future refer-
ence.
For personal safety and proper operation and mainte-
nance of the tool, read this instruction manual before
using the tool.
General safety
• Do not permit those uninstructed to use the tool.
• No horseplay. Respect the tool as a working imple-
ment.
• Do not operate when under the influence of alcohol,
drugs or the like.
• Never alter the tool.
6
Explanation of general view
9
Screw
10 Hook
11 Protrusion
12 Nose adapter
13 Contact element
14 Lever
15 Door
16 Adjustfit
17 Change plate
Wire-collated coil nail 200 pcs., 400 pcs.
Personal protective equipments
• Always wear safety glasses to protect your eyes from
dust or fastener injury.
WARNING: It is an employer's responsibility to enforce
the use of safety eye protection equipment by the tool
operators and by other persons in the immediate work-
ENE059-1
ing area.
For Australia and New Zealand only
Always wear safety glasses and face shield to protect
your eyes from dust or fastener injury. The safety
glasses and the face shield should conform with the
requirements of AS/NZS 1336.
ENB109-5
000114
• Wear hearing protection to protect your ears against
exhaust noise and head protection. Also wear light but
not loose clothing. Sleeves should be buttoned or
rolled up. No necktie should be worn.
18 Arrow
19 Nail guide
20 Feeder
21 Trigger
22 Workpiece
23 Change lever
24 Cap
25 Drain cock
AN510H
0.98 – 2.26 MPa (9.8 – 22.6 bar)
Wire-collated coil nail 27 mm – 50 mm
Sheet-collated coil nail 25 mm – 50 mm
Sheet-collated coil nail 200 pcs.
5.0 mm
ISO VG32 or equivalent
260 mm x 255 mm x 111 mm
1.4 kg
Safety glasses
Face shield