Operating Instructions
INDICATOR LIGHT FUNCTIONS
Note: Depending on the humidity conditions of the surrounding environment, the dehumidifi er may not start automatically
when the "on/off" button is pressed (see dehumidifying mode instructions for details).
9. Bucket Full Indicator Light: When the bucket is full and/or incorrectly positioned inside the cabinet, the bucket full
light will turn on and remain on until the bucket is emptied and/or correctly re-positioned. This condition will result in the
immediate shut down of the dehumidifying system (both compressor and fan motor operation are terminated). This is a
safety feature. When the bucket is emptied and/or correctly re-positioned, the dehumidifi er will resume operation automat-
ically. NOTE: It may take several minutes before operating conditions resume.
10. Auto-defrost: When frost builds on the evaporator coils, the compressor will cycle off and the fan will continue to run
until the frost disappears.
NOTE:
Memory Setting: Each time the unit is disconnected / re-connected and/or in the event of a power failure, the electronic
circuit board automatically defaults to the last program setting that was used. After the unit has stopped, it may take sev-
eral minutes before operating conditions resume.
Auto-restart: If the unit shuts off unexpectedly due to a power outage, it will restart with the previous function settings
automatically when the power resumes.
ERROR CODES
AS - Humidity sensor error -- Unplug the unit and plug it back in. If error repeats, call for service.
ES - Temperature sensor error -- Unplug the unit and plug it back in. If error repeats, call for service.
P2 (or Eb) - Bucket is full or the bucket is not in correct position -- Empty the bucket and/or adjust it to the proper position.
EC - Please ensure that the room ambient temperature matches the recommended operating temperature for the unit,
5°C (41°F) - 35°C (95°F). If the temperature is within this range, call for service.
E3 - Unit Malfunction, unplug the unit and plug it back in. If error repeats, call for service.
TIMER FUNCTIONS
Follow these steps to program the Auto-on or Auto-off feature using the control panel:
Auto-off:
1. When the unit is on, and the TIMER button is pressed, the timer off indicator light illuminates to indicate that the auto-
off program is initiated.
2. Press or hold the UP or DOWN button to change the 'Auto' time by 0.5 hour increments, up to 10 hours (then at 1 hour
increments up to 24 hours). The unit control will count down the time remaining until start.
3. Within 5 seconds of setting auto-off time, press the TIMER button again to complete the auto-off program.
Auto-on:
4. When the unit is off, and the TIMER button is pressed, the auto-on program is initiated. Set the auto-on time as in step
2 above. Within 5 seconds of setting auto-on time, press the TIMER button again to complete the auto-on program.
NOTE: When the auto-on and auto-off times are set, within the same program sequence, TIMER ON OFF indicator lights
illuminate indicating that both ON and OFF times are now programmed.
NOTE: Turning the unit ON or OFF at any time, changing the on/off timer setting to 0.0, and a P2 error code will cancel the
Auto-on/off functions.