vitapur VUV-S375MA Instrucciones De Instalación Y Manual Del Propietario página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

p
rocedure for
• Depressurize chamber by turning off the inlet water supply and open valve downstream of system. Then close
outlet valve.
• Unplug the ballast from the electrical outlet.
• Allow at least 5 minutes for lamp to cool.
• Remove the connector from the end of the UV lamp.
• Remove the UV lamp from the quartz sleeve by gently rotating the lamp free. Be sure to hold the lamp only
by the ceramic tips.
• Insert the new UV lamp into the quartz sleeve and attach the connector.
• Repressurize system by slowly opening water inlet valve.
• Check the system for leaks.
• Plug in ballast to the electrical outlet.
• Ensure that the UV lamp is operating – the green power LED light should be illuminated, the red lamp failure
LED light should be off and no audible alarm should be active.
• Display will show number of days until lamp replacement is required. If a new lamp was installed. Press and
hold button on ballast for 10 seconds to reset countdown timer.
Mineral deposits and sediment build-up on the quartz sleeve will affect the system performance by decreasing
the UV light transmitted through the quartz sleeve into the water column.
The proper maintenance and replacement of the pre-filtration required for the UV system will reduce the
accumulation of mineral and sediment residue on the quartz sleeve.
The quartz sleeve may be cleaned with a commercially available, non-abrasive, scale remover (should be acidic)
and a lint free cloth. Cleaning of the quartz sleeve should be done on a regular basis to ensure maximum system
performance. The amount of cleaning required will vary depending upon local water conditions.
All traces of the cleaning solution must be fully removed from the sleeve before it is reinstalled in the system.
Care should be taken to prevent any cleaning fluid from coming into contact with the inside surface of the
quartz sleeve.
Model #
VUV-S375B
S
VUV-S375MB
O
VUV-S375MA
S
VUV-S645B
E
VUV-S645MB
R
VUV-S645MA
I
VUV-S940B
E
VUV-S940MB
S
VUV-S940MA
VUV-H375B
H
VUV-H375MB
O
VUV-H375MA
VUV-H645B
S
VUV-H645MB
E
VUV-H645MA
R
I
VUV-H940B
E
VUV-H940MB
S
VUV-H940MA
r
/ I
eplacIng
Replacement Parts
Ballast
UV Lamp
BA-40S
GUVL-330S
BA-40S
GUVL-600S
BA-40S
GUVL-893S
BA-95H
GUVL-330H
BA-95H
GUVL-600H
BA-95H
GUVL-893H
u
nStallIng the
9
Quartz Sleeve
GQS-330D
GQS-600D
GQS-893D
GQS-330D
GQS-600D
GQS-893D
(uv) l
ltravIolet
:
amp

Publicidad

Tabla de contenido
loading

Tabla de contenido