Specifications:
Model number:
Flow Rate GPM US (LPM) (I)
Ballast
Chamber Diameter
Chamber Length
I/O Port Size
System Maximum Operating Pressure
Voltage
Power Consumption (W)
Lamp Watts (W)
Chamber Material
* Class B rated flow at least equivalent to 16 mJ/cm
w
Q
ater
ualIty
Water quality will adversely affect the performance of your Vitapur® UV disinfection system, and the
following levels should be utilized as a guideline for pre-treatment requirements of the influent water
supply prior to UV treatment:
Iron
Turbidity
Tannins
Manganese
Hardness
%UVT (transmittance) Must be greater than 75%
If you are using untreated surface water or untreated groundwater as your source of supply, the
suitability of the water supply for potable applications must be confirmed by the provincial / state
and/or local health agency that has jurisdiction.
If the test results indicate that: (1) any of the above contaminant levels are being exceeded, or (2)
any prevailing drinking water health standards are not being met, additional pre-treatment options
must be installed that will eliminate all contaminants posing health risks. Non-municipal water should
be tested on an ongoing basis to ensure treatment efficiency.
NSF/ANSI Standard 55 Class B and CSA B483.1
VUV-S375B
VUV-S375MB
7.4 (28.2)
3.5" (8.9 cm)
17.25" (43.8 cm) 27.88" (70.8 cm) 39.5" (100.3 cm)
21
17
p
:
arameterS
Total iron count must be less than 0.3 ppm (0.3 mg/L)
Count must be less than 1 NTU
Count must be less than 0.1 ppm (0.1 mg/L)
Count must be less than 0.05 ppm (0.05mg/L)
Count must be less than 120 ppm (7 grains per gallon)
VUV-S645B
VUV-S940B
VUV-S645MB
VUV-S940MB
12.3 (46.6)
18.7 (71.1)
8" x 3" x 2" (20.3 cm x 7.6 cm x 5.1 cm)
3.5" (8.9 cm)
3.5" (8.9 cm)
3/4" FNPT - 1.0" MNPT
125psi (862 kPa)
100-240, 50/60Hz
35
42
30
35
304SS
2
4
VUV-H375B
VUV-H645B
VUV-H375MB
VUV-H645MB
15.8 (60)
26.4 (100)
3.5" (8.9 cm)
3.5" (8.9 cm)
17.25" (43.8 cm) 27.88" (70.8 cm)
46
67
40
60
VUV-H940B
VUV-H940MB
40.4 (153)
3.5" (8.9 cm)
39.5" (100.3 cm)
98
90