Ingersoll Rand ARO 65814 Serie Informacion General página 5

Bombas de pistón neumáticas o hidráulicas
Ocultar thumbs Ver también para ARO 65814 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
GENERAL PRODUCT SAFETY INFORMATION
EXCESSIVE INLET AIR / HYDRAULIC PRESSURE.
WARNING
Can cause personal injury, death, pump damage or prop-
erty damage.
Do not exceed the maximum inlet air / hydraulic pressure
as stated on the pump model plate.
Be sure material hoses and other components are able to
withstand fl uid pressures developed by this pump. Dam-
aged hose could leak fl ammable liquids and create poten-
tially explosive atmospheres. Check all hoses for damage
or wear. Be certain dispensing device is clean and in prop-
er working condition.
Do not exceed the maximum material pressure of any
component in the system.
A pressure relief valve must be used to prevent overpres-
surization of the system and possible component rup-
ture.
HAZARDOUS MATERIALS. Can cause serious in-
WARNING
jury or property damage. Do not attempt to return a pump
to the factory or service center that contains hazardous
material. Safe handling practices must comply with local
and national laws and safety code requirements.
Obtain Material Safety Data Sheets on all materials from
the supplier for proper handling instructions.
MAXIMUM SURFACE TEMPERATURE LIMITS.
WARNING
Maximum surface temperature depends on the operating
conditions of the pump. Do not exceed maximum temper-
ature limits as noted on page PTL-1.
Do not allow the pump to run dry. Pump surface tempera-
tures will rise and temperatures may exceed maximum
temperature limits of packings, as noted on page PTL-1.
Ensure proper housekeeping to eliminate dust buildup on
the pump. Certain dusts may ignite at pump surface tem-
perature limits, as noted on page PTL-1.
Excessive hydraulic oil temperatures can cause fi re. The
hydraulic motor is rated for operation up to 130˚ F (54˚ C).
Maximum temperatures are based on mechanical stress
only. Certain chemicals will signifi cantly reduce maximum
safe operating temperature. Consult the chemical manu-
facturer for chemical compatibility and temperature limits.
All Pumps.
WARNING
Leaking Fluids can cause explosion hazards.
Re-torque all pipe and hose fi ttings to insure against fl uid
leakage.
Pump damage caused by improper mounting or piping
stress and external damage can result in fl uid leakage.
Barrel pumps must be removed from the container when
not in use.
Inlet of pumps must always be submerged in media being
pumped.
GENERAL INFORMATION // AIR / HYDRAULIC OPERATED PISTON PUMPS
Pumps must never be run dry.
Leakage from the hydraulic motor weep hole should be
inspected daily. Seals must be replaced if leakage exceeds
5 cc/ day.
HAZARDOUS PRESSURE. Can result in serious
WARNING
injury or property damage.
Do not service or clean pump, hoses or dispensing valve
while the system is pressurized.
Disconnect air / hydraulic supply line and relieve pressure
from the system by opening dispensing valve or device
and / or carefully and slowly loosening and removing out-
let hose or piping from pump.
INJECTION HAZARD. Any material injected into
WARNING
fl esh can cause severe injury or death. If an injection oc-
curs immediately contact a doctor.
Do not grab front end of dispensing device.
Do not aim dispensing device at anyone or any part of the
body.
Verify the chemical compatibility of the pump
CAUTION
wetted parts and the substance being pumped, fl ushed
or recirculated. Chemical compatibility may change with
temperature and concentration of the chemical(s) within
the substances being pumped, fl ushed or circulated. For
specifi c fl uid compatibility, consult the chemical manufac-
turer.
Protect the pump from external damage and do
CAUTION
not use the pump for the structural support of the piping
system. Be certain the system components are properly
supported to prevent stress on the pump parts.
Suction and discharge connections should be fl exible con-
nections (such as hose), not rigid piped, and should be
compatible with the substance being pumped.
Be certain all operators of this equipment have
CAUTION
been trained for safe working practices, understand it's
limitations, and wear safety goggles / equipment when
required.
en-2

Publicidad

Tabla de contenido
loading

Tabla de contenido