Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Warning!
Operate this valve only in conjunction with the correct grit filter.
Failure to observe can lead to a damaged fitting.
Important!
Before installing, flush the pipes in compliance with DIN 1988.
The water outlet of the fitting must always be kept free. Do not use an aerator.
To protect the tiles, use masking tape when marking and drilling. Drill at low speed.
Depending on the composition of the wall, special wall dowels may have to be used
(to be provided by the customer).
10.1 The corner valves (a) must be provided by the customer.
10.2 Installing the hot water heater
Observe the operating instructions for the hot water heater.
When installing a new socket outlet, take into account the length of the power cable
of the hot water heater.
10.3 Install the fitting (b) on the washbasin (c).
10.4 Place the flow rate regulator (g) into the connector piece (f).
10.5 Place the seal (e) on the connector piece (f).
Screw the water supply hose (d) on to the connector piece (f). Loosen the connector
piece by unscrewing it 1-2 turns.
10.6 Connect the hoses between the hot water heater and the fitting.
1 Cold water (blue)
2 Hot water (red)
10.7 Place the grit filter (3) on the corner valve.
10.8 Screw the connection piece on to the corner valve.
10.9 Screw the water supply hose on to the connector piece.
10.10 Insert the power plug in the socket.
Connect the cable between the fitting and the power supply.

11. Commissioning

11.1 Open the water supply.
Caution!
First fill the hot water heater tank.
11.2 Insert the power plug in the socket.
Observe the operating instructions for the hot water heater.
6
info@hygiene-shop.eu - www.hygiene-shop.eu

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

76129821846422000105120

Tabla de contenido