In the case of problems, the following error messages may appear on the display:
Error message
E01
E02
E03
E06
E07
E08
The unit is in
stand-by mode,
no information
shows on the
display, and beep
signals are heard
Troubleshooting
Cause
The mains voltage is
below 160 V.
The mains voltage
exceeds 270 V.
Internal fault
Internal fault
The cooking
temperature exceeds
240 °C.
Internal fault
Unsuitable cookware
(non-magnetic base,
diameter less than
18 cm)
Action to be taken
Connect the unit to an outlet installed
in accordance with the regulations,
with a supply voltage between 220
and 240 V.
Connect the unit to an outlet installed
in accordance with the regulations,
with a supply voltage between 220
and 240 V.
Contact customer service.
Contact customer service
Turn the unit off, disconnect it from
the mains and allow it to cool down.
Contact customer service if the
problem occurs repeatedly.
Contact customer service.
See 'Suitable cookware' section
17