Textron GREENLINE CM-900 Manual De Instrucciones página 13

Medidores digitales con pinza
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Accuracy
Refer to "Specifications" for operating conditions and temperature coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed amount) at
18 °C to 28 °C (64 °F to 82 °F), 0% to 80% relative humidity
AC Current
Range
0.0 to 320.0 A
400.0 A
320.0 to 400.0 A
600 A
± 1.0% position error
AC Voltage
Range
± (1.0% + 0.5 V)
400.0 V
± (1.0% + 5 V)
600 V
CM-900 is average sensing, RMS calibrated.
CM-950 is true RMS sensing. Accuracy is specified for sine waves at full scale and non-sine
waves below half scale. For non-sine waves, add the following crest factor corrections:
• Crest factor 1.4 to 2.0, add 1.0%
• Crest factor 2.0 to 2.5, add 2.5%
• Crest factor 2.5 to 3.0, add 4.0%
Maximum crest factor is 3 at 400 A or 400 V, and 2 at 600 A or 600 V.
Input Value
400 to 600 A
Accuracy
Accuracy (50 to 60 Hz)
± (1.5% + 0.5 A)
± (3.1% + 0.5 A)
± (2.0% + 7 A)
Frequency Response
50 to 500 Hz
CM-900 • CM-950
Accuracy (61 to 400 Hz)
± (2.0% + 0.5 A)
± (3.6% + 0.5 A)
± (2.5% + 7 A)
Input Impedance
1 MΩ || < 100 pF