Warning: if the power cable is damaged, it must be replaced by the manufacturer, his service agent, or
a similar qualified person in order to avoid any hazard.
5.
To point the lamp in the desired direction: loosen the hinges using a screwdriver.
6.
Tilt the lamp in the desired angle and tighten the hinges.
5. Sensor controls
LUX: The device can distinguish between day and night thanks to the adjustable ambient light
setting. The device can work in the daytime when the "sun" (max.) position is selected with the
selector. When set to "moon", the sensor remains inactive during daylight. To set the sensitivity
level, wait until it gets darker and set the sensitivity you want.
TIME: Use the time adjustment control to set how long the floodlight will stay on after the motion
has been detected (10 seconds (+/- 3 seconds) to 9 minutes (+/- 3 minutes)).
SENS: Use the sensitivity adjustment control to set the sensitivity of the floodlight. Turn to the left
to decrease the sensitivity, turn to the right to increase.
6.
Cleaning and Maintenance
This luminaire does not have a built-in device to disconnect it from the electric mains. Make sure to
electrically isolate the luminaire before installation or maintenance activities are performed.
All screws should be tight and free of corrosion.
The housing, the visible parts, the mounting supports and the installation location (e.g. ceiling,
suspension, trussing) should not be deformed, modified or tampered with; e.g. do not drill extra
holes in mounting supports, do not change the location of the connections...
The electric power supply cables must not show any damage. Have a qualified technician maintain
the device.
If the protective glass is damaged, disconnect the lamp immediately from the mains. Have it repaired
immediately by a qualified technician. Do not use the lamp with a cracked or broken protective glass.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.
7.
Technical Specifications
body colour
electrical data
power LED module
total nominal power
nominal voltage driver
power factor
energy consumption
IP rating
V. 01 – 09/08/2017
LEDA600xNW-BP
N = neutral, blue
E = earth, yellow/green
L = line, brown
LEDA6001NW-BP
15x SMD 2835 LEDs
10 W
10 kWh/1000 h
4
LEDA6002NW-BP
black
28x SMD 2835 LEDs
220-240 V~
> 0.5
20 kWh/1000 h
IP54
20 W
©Velleman nv