Dip Switches; Cleaning And Maintenance - HQ-Power VDPL300QF2 Manual Del Usuario

Ocultar thumbs Ver también para VDPL300QF2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

To set the device to work with a DMX controller:
1. On the back panel [5], set DIP switches 9 and 10 to OFF.
2. Use DIP switches 1 – 8 to specify the DMX address:
address

DIP switches

5
19
40
DMX channel values
Channel
From
0
7
1
67
130
193
0
7
2
67
130
193
0
7
3
67
130
193
0
4
7
0
5
31
0
6
31
0
7
31
Notes
CH1 to CH4 can work together with CH5; the values of CH5 must be set between 0 and 30.
When using CH 6, the values of CH5 must be set between 31 and 255.
You can use CH1 to CH6 together with CH7 for strobe effects.
Channel 7 (strobe) only works if other channels (CH 1 to CH 6) are active.
8.

Cleaning and maintenance

All screws should be tightened and free of corrosion.
The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension,
trussing) should not be deformed, modified or tampered with; e.g. do not drill extra holes in mounting
supports, do not change the location of the connections...
Moving mechanic parts must not show any signs of wear and tear.
V. 03 – 22/06/2012
VDPL300QF2
To
Function
6
Off
66
Group 1 red lights on
129
Group 2 red lights on
192
Group 3 red lights on
255
All red lights on
6
Off
66
Group 1 green lights on
129
Group 2 green lights on
192
Group 3 green lights on
255
All green lights on
6
Off
66
Group 1 blue lights on
129
Group 2 blue lights on
192
Group 3 blue lights on
255
All blue lights on
6
Off
255
All white lights on
30
Off
255
Built-in program (speed increases according to channel settings)
30
Automatic
255
Built-in program
30
Strobe effect off
255
Strobe effect (speed increases according to channel settings)
switch
represents
1
1
2
2
3
4
4
8
5
16
6
32
7
64
8
128
6
©Velleman nv

Publicidad

Tabla de contenido
loading

Tabla de contenido