Example: You would like to lift a plateof S235 which is 6 mm thick. The plate stands vertically in your shelf (i.e. at
an angle of 90°) and your magnet is ideally positioned, as shown in figure 1.
Material thickness:
Material:
Alignment of the load: 90° tilted; load swivel facing upwards
Maximum load weight with 3:1 safety factor= 90 kg x 100 % x 30 % = 27 kg
6 mm → max. load-bearing capacity at 0° = 90 kg (see table 2)
S235 →holding force, subject to material = 100 % (see table 1)
→Load-figure corresponding to direction = 30 %
19