Detailed performance data for the TML 90
Values shown for load capacity of the TML 90
force with 0° deviation from the load axis and additionally under a 90° inclined load. The safety factor corresponds
to at least 3:1 in all cases.
Tabelle 3: Round pipes
mm
25
>5
4
3
2
inch
1"
>0.2
0.16
1/8
0.08
Avoid quick and abrupt rotations of the lifting magnet especially when used on round objects
since the workpiece could disengage from the groove of the magnet and the load-bearing
capacity would suddenly be reduced.
Never exceed the dimensions and/or the load-bearing capacity of the material thickness given
intable 2 & 3.
R
are based on material S235 JR for the maximum, vertical tractive
Load capacity in kg
50
75
30
40
27
36
26
34
24
32
Load capacity in lbs
2"
3"
66
88
59
79
56
75
53
70
R
lifting magnet on round pipes
100
200
45
40
-
42
36
-
40
34
-
38
32
-
4"
8"
100
88
-
92
79
-
88
75
-
83
70
-
23