6.3
Mains power supply
Check that the unit is connected to the correct mains power supply voltage, and that
it is protected by the correct fuse size. A protective earth connection must be made,
in accordance with regulations.
Recommended fuse sizes and minimum cable area
Mig C160i
Mains voltage
Mains cable area mm
Phase current, I
eff
Fuse anti-surge
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. Use the power source in accordance with the relevant national regulations.
Extension cable
If needed, it is recommended to use an extension cable, 3x.10 "
length of 164 ft.
Supply from power generators
The power source can be supplied from different types of generators. However,
some generators may not provide sufficient power for welding. The generators with
AVR, equivalent or better type of regulation with rated power 5.5...6.5 kW are
recommended to supply the power source within it's full capacity.
It is also possible to use generators with lower rated power, starting from 3.0kW, but
in that case the setting must be proportionally limited. The power source is protected
against undervoltage. If the power supplied by the generator is not sufficient, the
welding is interrupted. Especially the welding start could be disturbed. In case of
disturbed welding process, either adjust the welding parameters or change to a more
powerful generator.
bc21a
Rating plate with supply connection data
230 V 15% 150/60 Hz
2
2
3G.060 "
10 A
16 A
- 13 -
2
of a maximum