Mains Power Supply - ESAB Migmaster 215 Pro Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GB
Welding voltage polarity
Welding voltage polarity may be changed as shown below.
5.3

Mains power supply

Check that the unit is connected to the correct mains power supply voltage, and that
it is protected by the correct fuse size. A protective earth connection must be made,
in accordance with regulations.
Voltage V
Current A
at 100% duty cycle
at 60% duty cycle
at 20% duty cycle
Cable area AWG
Fuse slow A
MM215Pe
Rating plate with supply connection data
Migmaster 215 Pro
208/230V, 1∼ 50/60Hz
19/17
30/27
56/50
3 x 10
35
- - 8 - -
Migmaster 215 Pro
208/230/460/575V, 1∼ 50/60Hz
19/17/9/7
30.5/27.5/14/11
58/53/26/21
3 x 10
35/35/20/16

Publicidad

Tabla de contenido
loading

Tabla de contenido