Page 5
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
STANDARD OR MULTI-
FUNCTION WALL SWITCHES
SENSOR/
CONTROL
BLK
WHT
120 VAC
LINE IN
GRD
BLACK
WHITE
SENSOR
MANUAL
CONTROL
ON
SWITCH*
SWITCH*
* purchase separately
Attach cable clamp to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
2
Connect wires
MANUAL-ON
RED
ORANGE
BROWN
GROUND
(green or bare)
SWITCH BOX
120 VAC
LINE IN
14/3
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
RED
BLK
WHT
GRD
RECEPTACLES
KNOCKOUT
PLATE
XB110H Installation Guide
3
4
Screw from
Parts Bag
RED
FAN
BLK
ORG
SENSOR/
CONTROL
BRN
WHT
• See OPERATION section on page 12
for details.
• SENSOR/CONTROL switch turns
humidity control on for automatic
operation and off for fan cleaning and
maintenance purposes.
• MANUAL-ON switch directly turns fan
on/off.
• MANUAL-ON switch is not required to
manually turn fan on (see page 10).
• SENSOR/CONTROL switch may be
located where it is not easily accessed
for everyday usage; it may need to
be labeled and located where it can't
be turned on without being seen from
fan to comply with local and national
codes.