Manual Mode; Pulse" Mode - Sagola Dry Tech DT3/6 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

20/21
The time and power of each step can be adjusted during execution, but it won't change the default
data.
If you want to change the default data of automatic mode, adjust the parameters as follows before
pressing "Start":
1. Once switching on the power supply, the display automatically defaults to Step 1 of the
automatic mode.
2. Press "Routine" once, switches to Step 2; press again, switches to reserve 1 or reserve 2.
3. When switch to each step, adjust the time and power by Button 2 and 4, stay unchanged
for 3 seconds then the data will be automatically saved as default setting for this step.
4. To initialize all data, press and hold the distance adjustment buttons + and - at the same
time.
** (DT3 / DT6 models, reserve1 and reserve 2 modes are disabled)
- Protect the lamp against shocks and vibrations when the lamp is in use.
- After this program is completed, the system is able to carry out other programs. Make sure to turn
off the system when the equipment is not in use and keep the equipment securely in place.

7.3. Manual Mode

- Press the button "Auto" to shut down the automatic mode.
- Press the button to select "Routine" or "Pulse".
- Press the button "Start".
- The curing distance between the cassette and paint surface should be set according to the paint
material and weather (air humidity). Usually, keeping a distance of about 35-45 cm. from the paint
surface is recommended.
- The curing time and power should be set according to the requirements of the paint material.
Usually, "Pulse" is set to 5 mins and "Routine" to 10 mins.
- Press the button "Start/Stop".
- Turn off the equipment when the work is completed.

7.4. "PULSE" Mode

- Press the button "Auto" when the lamp is
ready to use to shut down the automatic
mode. Set power and time. Press the button
"Pulse".
- Press the button "Start/Stop".
- The curing distance between the emitters
and paint surface should be set according
to the material of paint and weather (air
humidity). Usually, keeping a distance of
about 35-45 cm. from the paint surface is
recommended.
- After this program is completed, the system is able to carry out other programs. Make sure to turn
off the system when the equipment is not in use.