Installation Instructions

Rough-in Installation
Control valve assembly, piping
and fittings
Reference as required:
Visual Guide ...................................1
Dimensions illustration ................4
1)
Determine wall thickness
Determine type of wall and wall
thickness where valve will be
mounted as follows:
Fiberglass or acrylic walls:
Thickness =
1/2" (13 mm)
Dry wall, plaster, or other type
walls:
Thickness = more than
Skip ahead to step 3
(13mm)
2)
Attach mounting plate
Seat plate against valve assembly.
Figure 1 Mounting plate
Walls for using T-177 mounting plate
 Fiberglass or acrylic walls (required)
 Plaster or other type walls (optional)
1/16" (2 mm) min  1/2" (13 mm) max
Protective shield
When mounting plate is used,
then shield is optional for
protecting end of valve during
installation.
"snap on-off"
p/n T-176
wall cutout hole size
3-1/2" (89 mm) min
4" (102 mm) max
3) Attach protective shield
Attach plastic protective shield
by snap fitting over end of valve
spindle as shown in Figure 2.
Page
4)
Install control valve
Install through cutout hole in wall
as specified in Figure 2 below and
Dimensions illustration on page 4.
5)
Install piping and fittings
Piping and fittings not supplied.
Showerhead (S on valve)
Pipe from outlet port on valve
or less
marked
mounting arm location.
Hot & Cold Supply (H & C)
1/2"
Pipe hot water supply to valve
input marked
supply to valve input marked
6)
Remove protective shield
Remove shield snap fitted over
the end of valve spindle after
valve is securely installed.
7) Adjust valve packing nut
■ Turn hot & cold supplies on.
Valve will not operate unless
both hot and cold water supply
pressure are turned on.
nished
wall
p/n T-177
Figure 2 Mounting valve
to showerhead
S
and cold water
H
C
Dry wall, plaster or other type wall
1/2" (13 mm) or greater
Ensure valve's
mounting plate
is ush against
inner wall
Finished wall must be
ush with back side of
protective shield surface
Protective shield
"snap on-off"
(required when
mounting plate
is not used)
wall cutout hole size
3-1/2" (89 mm) min
4" (102 mm) max
Page 2
■ Place handle over end of control
spindle stem. Tighten packing
nut for positive frictional
resistance as handle is rotated
from shutoff position across
adjustment range.
8)
Flush system and check
for leaks
Temp Limit
stop screw
packing nut
control
spindle
stem
.
Figure 3 Limit stop screw
■ Turn valve to the warm position
and run for a few minutes.
■ If system is dirty, remove valve
spindle in valve to ensure
proper flushing. See service
instructions.
Do not install positive
Note:
shut-off devices on valve
outlet or devices that do not
allow the valve to flow at least
1 GPM at 50 psi inlet pressure.
nished wall
2-3/8" ± 1/2"
(60 mm ± 13 mm)
pipe centerline
to nished wall
wall