Installation Instructions - Symmons Callie S-7102-RP Instrucciones De Instalación Y Servicio

Sistema de bañera y ducha
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions

Rough-in Installation
Control valve assembly, piping
and fittings
Reference as required:
Visual Guide ...................................1
Dimension illustration ..................4
1)
Determine wall thickness
Determine type of wall and wall
thickness where valve will be
mounted as follows.
Fiberglass or acrylic walls:
Thickness =
1/2" (13 mm)
Dry wall, plaster, other type:
Thickness = more than
Skip ahead to step 3.
(13 mm)
2)
Attach valve mounting plate
Seat plate against valve assembly.
Figure 1 FG-1 type mounting
Wall thickness when using
Protective shield, snap on-off
(
optional use for protecting end of
valve when applying plaster to wall)
p/n T-176
3-3/4" ( 95 mm) min
3)
Remove protective shield
Remove shield snap fitted over
the end of valve spindle as shown
in figure 2 below.
Page
4)
Install control valve
Install through cutout hole in wall
as specified in figure 2 below and
Dimension illustration on page 4.
5)
Re-attach protective shield
(optional, reference figure 2 to
determine usage) Attach plastic
protective shield by snap fitting
or less
over end of valve spindle.
6)
Install piping and fittings
1/2"
Piping and fittings not supplied
Showerhead (S on valve)
Pipe from outlet port on valve
marked
mounting arm location.
Hot & Cold Supply (H & C)
Pipe hot water supply to valve
input marked
supply to valve input marked
Tub Spout (T on valve)
Pipe from outlet port on valve
marked
7)
Remove protective shield
If re-attached in Step 5, then
remove shield snap fitted over
the end of valve spindle once
plate
valve mounting plate
1/16" (2 mm) min
1/2" (13 mm) max
nished wall
p/n T-177
cutout hole size
4" (101 mm) max
Figure 2 Mounting valve
to showerhead
S
and cold water
H
C
to tub spout.
T
Ensure valve's
FG-1 mounting
plate is ush
against inner wall
Page 2
valve is securely installed and
wall finish work has been
completed.
8)
Adjust valve packing nut
■ Turn hot & cold supplies on.
Valve will not operate unless
both hot and cold water supply
pressures are turned on.
■ Place handle over end of control
spindle stem.
nut
for
positive
resistance as handle is rotated
from shutoff position across
adjustment
figure 3 below.
packing
nut
control
spindle
stem
Temp.
limit stop
adjust
.
Figure 3 Valve adjustments
9)
Flush system and check
for leaks
■ Turn valve to the warm position
and run for a few minutes.
■ If system is dirty, remove valve
spindle in center of valve to
Wall thickness without
valve mounting plate
1/2" (2 mm)
or greater
nished wall
Pipe centerline
to nished wall
2-3/8" ± 1/2"
(60 mm ± 13 mm)
Finished wall must
be ush with back
side of this surface
snap on-off
protective shield
cutout hole size
3-1/2" ( 89 mm) min
4" (101 mm) max
Tighten packing
frictional
range.
Reference
wall