if the Spa-pack purchased is a type "with heat exchanger", the
primary water circuit of the exchanger must also be connected
to a boiler (see HEAT EXCHANGEr CONNECTiONS - fig 7).
The Spa-pack must always be installed in an enclosed but
ventilated space, inaccessible except with keys or special tools,
and protected from water and weather.
The temperature in the enclosure housing the Spa-pack
must not exceed 40 °C, otherwise the pumps may not cool
properly and the integrity of the electronic control
equipment could be affected.
Overflow tank
The tank must be installed at the same height or lower, close to
the minipool, but no more than 2 metres lower.
in the event of the overflow tank being installed outdoors,
prevent any risk of damage by adopting a system to ensure
protection from direct sunlight, ultraviolet radiation and extreme
weather conditions.if the pool is to be used in winter, it may be
useful to insulate the overflow tank.
3
PLACEMENT
Move the minipool into its final position, with the plumbing
fittings directed toward the channel carrying the pipelines away
from the pit.
Set the pool perfectly level by adjusting the feet.
4
5
PLUMBING CONNECTIONS
The contractor will supply all the plumbing material (including
fittings, ball valves, etc.), needed to connect the minipool to the
Spa-pack and to the overflow tank, and must install suitably
proportioned gullies, inspectable and accessible for cleaning
purposes, into which the drain pipelines will be directed.
DRAIN: the contractor must install a Tee and a relative valve on the
pipeline connecting the outlet side of the filtration pump to the pool.
The drain line to the gully C can take the form of a hose
connected to the valve on the Tee, or alternatively, a permanent
drain line can be installed.
In particularly cold climates, where there is a risk of
residual water freezing in pipelines, it is advisable to install
drain valves at strategic points on the various circuits, so
that the system can be emptied completely.
The drain line (11) from the overflow tank must be connected to
a gully C, as also must the line from the overflow (7) of the tank.
in this case, the connection must strictly be of the "ventilated"
type; for example, using a water inlet non-return valve to avoid
dirty water being sucked back into the circuit as a consequence
of the variations in level due to utilising the mini-pool.
Where a sand filter is installed, the plumbing connections to the
Spa-pack must also include a connection between the
backwash valve (W) and the drain gully C.
IMPORTANT: before making any permanent connection to the
main drain, contact the local authorities to check on
regulations governing the disposal of chemically treated water.
FILLING: the recommended method of filling the Teuco is to
use an ordinary hose, taking care not to immerse the end as
this could allow reflux of water back into the main.
IMPORTANT: the solenoid valve (8) supplied with the pool
must be connected to the cold water supply and to the
overflow tank by the contractor, who will select the most
convenient location compatible with the length of the
power cable. The hydraulic supply pressure must be
between 0.1 and 10 bars. Install a filter on the supply
network to protect the components from impurities, sand
and suspended particles.
The hydraulic supply pressure must be between 0.1 and
10 bars. Install a filter on the supply network to protect the
components from impurities, sand and suspended
particles.
Install the "water load anti-reflux safety" device (10)
provided.
IMPORTANT: if the intention is to connect the minipool
permanently to the water supply, suitable non-return devices
must be incorporated to prevent reflux back to the water main.
Contact the local authorities before proceeding with this type
of installation.
ATTENTION: For safety reasons, install the air inlet tubing that
connects the blower to the mini-pool in such a way that there is
an elevation along the route of the tubing of at least 500mm
above the maximum level of water that can be reached in the
mini-pool.
17