Water Pressure
A cold water supply with water pressure of between 30 and
120 psi (207 and 827 kPa) is required to operate the water
dispenser and ice maker. If you have questions about your
water pressure, call a licensed, qualified plumber.
If your refrigerator has a water dispenser: After installation is
complete, use the water dispenser to check the water pressure.
With the water filter removed, dispense 1 cup (237 mL) of
water. If 1 cup of water is dispensed in 8 seconds or less,
the water pressure to the refrigerator meets the minimum
requirement.
If it takes longer than 8 seconds to dispense 1 cup of
water, the water pressure to the refrigerator is lower than
recommended. See the "Troubleshooting" section for
suggestions.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of
a reverse osmosis system going to the water inlet valve of the
refrigerator needs to be between 30 and 120 psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis system
needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than
40 to 60 psi (276 to 414 kPa):
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
If your refrigerator has a water filter, it may further reduce
the water pressure when used in conjunction with a reverse
osmosis system. Remove the water filter. See the "Water
Filtration System" section.
If you have questions about your water pressure, call a licensed,
qualified plumber.

CONNECT WATER SUPPLY

Read all directions before you begin.
IMPORTANT:
Plumbing shall be installed in accordance with the
International Plumbing Code and any local codes and
ordinances.
The gray water tubing on the back of the refrigerator (which
is used to connect to the household water line) is a PEX
(cross-linked polyethylene) tube. Copper and PEX tubing
connections from the household water line to the refrigerator
are acceptable, and will help avoid off-taste or odor in your
ice or water. Check for leaks.
Install tubing only in areas where temperatures will remain
above freezing.
TOOLS NEEDED:
Gather the required tools and parts before starting installation.
Flat-blade screwdriver
7/16" and 1/2" open-end wrenches or two adjustable
wrenches
1/4" nut driver
10
Connect to Water Line
IMPORTANT: If you turn the refrigerator on before the water line is
connected, turn the ice maker off.
Style 1 (Recommended)
1. Unplug refrigerator or disconnect power.
2. Turn off main water supply. Turn on nearest faucet long enough
to clear line of water.
3. Use a quarter-turn shutoff valve or the equivalent, served by
a 1/2" (12.7 mm) copper household supply line.
NOTE: To allow sufficient water flow to the refrigerator, a
minimum 1/2" (12.7 mm) size copper household supply line
is recommended.
D
A. Compression sleeve
B. Compression nut
4. Now you are ready to connect the copper tubing to the shutoff
valve. Use 1/4" (6.35 mm) OD soft copper tubing to connect
the shutoff valve and the refrigerator.
Ensure that you have the proper length needed for the job.
Be sure both ends of the copper tubing are cut square.
Slip compression sleeve and compression nut onto copper
tubing as shown. Insert end of tubing into outlet end squarely
as far as it will go. Screw compression nut onto outlet end
with adjustable wrench. Do not overtighten.
A
B
A. Compression sleeve
B. Compression nut
5. Place the free end of the tubing into a container or sink, and
turn on main water supply to flush out tubing until water is
clear. Turn off shutoff valve on the water pipe.
NOTE: Always drain the water line before making the final
connection to the inlet of the water valve, to avoid possible
water valve malfunction.
6. Bend the copper tubing to meet the water line inlet, which is
located on the back of the refrigerator cabinet as shown. Leave
a coil of copper tubing to allow the refrigerator to be pulled
out of the cabinet or away from the wall for service.
A
B
C
C. Copper tubing
D. Household supply line
(1/2" [12.7 mm] minimum)
C
C. Copper tubing

Publicidad