8

USING THE G4

BATTERY SPECS

The G4 is suitable for charging all types of 6V &12V lead-acid batteries,
including Wet (Flooded), Gel, MF (Maintenance-Free) and AGM (Absorption
Glass Mat) batteries. The G4 is suitable for charging batteries sized from 2.2 to
40Ah. The battery charger can also maintain all battery sizes.

CHARGE MODES

The G4 is equipped with four (4) charging modes per bank: 6V NORM, 6V
COLD/AGM, 12V NORM and 12V COLD/AGM. Before selecting a charge
mode, it is important to understand the differences and the purpose of each
mode. The charge modes are explained below:
MODE
EXPLANATION
6V NORM
The "normal" ("NORM") charge mode is for charging
7.2V
Wet Cell, Maintenance-Free and Gel Cell batteries. If
2.2-40Ah
you are unsure of the chemistry of your battery, use
1.1A (1100mA)
the NORM charge mode. When selected, a Red LED
Red LED
will illuminate.
6V COLD/AGM
The COLD/AGM charge mode is for charging
7.4V
batteries in cold weather and AGM (also known as
2.2-40Ah
"spiral wound") batteries. If a battery's (Wet, Gel, MF
1.1A (1100mA)
or AGM) temperature is below 32
Blue LED
COLD/AGM charge mode. If you are unsure of the
chemistry of your battery, DO NOT use this charge
mode, and use the NORM charge mode instead.
When selected, a Blue LED will illuminate.
12V NORM
The "normal" ("NORM") charge mode is for charging
14.4V
12V Wet Cell, Maintenance-Free and Gel Cell
2.2-40Ah
batteries. If you are unsure of the chemistry of your
1.1A (1100mA)
battery, use the NORM charge mode. When selected,
Red LED
a Red LED will illuminate.
o
F (0
o
C), use the
CHARGE MODES continued
MODE
EXPLANATION
The COLD/AGM charge mode is for charging 12V
12V COLD/AGM
batteries in cold weather and AGM (also known as
14.7V
"spiral wound") batteries. If a battery's (Wet, Gel, MF
2.2-40Ah
or AGM) temperature is below 32
1.1A (1100mA)
COLD/AGM charge mode. If you are unsure of the
Blue LED
chemistry of your battery, DO NOT use this charge
mode, and use the NORM charge mode instead.
When selected, a Blue LED will illuminate.
MASTER POWER BUTTON
The G4 is equipped with a master power button that turns the entire charger
ON or OFF. If power is lost or the unit is unplugged, the G4 will return to the
last selected power state when power is restored. In addition, all four (4) banks
will return to the last selected modes.
BATTERY BANKS
The G4 contains four (4) independent battery banks, or ports, that operate
individually and allow simultaneous charging of four (4) separate batteries or
banks. All four (4) banks function exactly the same and can be individually
configured to charge in any of the four (4) charging modes. Different battery
sizes, voltages (6V or 12V), and chemistries can be charged at the same time
by using different battery banks. When not in use, the banks go into STANDBY
mode. Keep unused banks sealed with the rubber port caps when not in use.
WICKED SMART TIP
Amp Hour (Ah) is a rating that measures a battery's storage capacity.
The Ah rating indicates how much amperage is available in the battery
over a twenty (20) hour period. In order to determine how many constant
Amps the battery can output for 20 hours, divide the Ah rating by 20. For
example, if you have a 100Ah battery, it can deliver 5 Amps for 20 hours
before it is fully discharged (100 / 20 = 5).