To remove the electrical wiring box cover
1 Remove the front grille.
2 Remove 1 screw from the electrical wiring box.
3 Open the electrical wiring box cover by pulling the protruding
part on the top of the cover.
4 Unhook the tab on the bottom and remove the electrical wiring
box cover.
a
b
a
c
a
Tab
b
Protruding part on the top of the cover
c
Screw
5 To re-install the cover, first hook the bottom tab onto the
electrical wiring box, and slide the cover into the 2 upper tabs.
To open the service cover
1 Remove 1 screw from the service cover.
2 Pull out the service cover horizontally away from the unit.
a
a
Service cover screw
b
Service cover
5.2

Installing the indoor unit

5.2.1

To install the mounting plate

1 Install the mounting plate temporarily.
2 Level the mounting plate.
3 Mark the centres of the drilling points on the wall using a tape
measure. Position the end of tape measure at symbol " ".
4 Finish the installation by securing the mounting plate on the wall
using screws.
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.