5.1.5
To re-install the front grille
1 Install the front grille and firmly engage the 3 upper hooks.
2 Install 2 screws (class 15~42) or 3 screws (class 50~71) back
on the front grille.
3 Install the air filter and then mount the front panel.
5.2
Installing the indoor unit
5.2.1
To install the mounting plate
1 Install the mounting plate temporarily.
Class 15~42:
a
137
d
a
e
68
170
Class 50~71:
a
122
142
d
a
e
48
170
(mm)
a
Recommended mounting plate fixing spots
b
Pocket for the pipe port cover
c
Tabs for placing a spirit level
d
Through-the-wall hole:
e
Drain hose position
f
Position for the tape measure at symbol " "
g
Gas pipe end
h
Liquid pipe end
CTXM15+ATXM20~50+FTXM20~71N2V1B
Daikin room air conditioner
3P482320-8K – 2018.09
b
c
a
c
213
h
g
a
50
337
810
b
c
PIPING HOLE
PIPING HOLE
CENTER:170mm
CENTER:170mm
TO THE LEFT
TO THE LEFT
447
i
j
2 Level the mounting plate.
3 Mark the centres of the drilling points on the wall using a tape
measure. Position the end of tape measure at symbol " ".
4 Finish the installation by securing the mounting plate on the wall
using M4×25L screws (field supply).
Class 15~42
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.
a
137
237
d
f
A
A
a
a
170
68
337
a
c
h
g
f
60
435
990
1040
5 Installation
Class 50~71
e
(mm)
a
126.5
151.5
PIPING HOLE
PIPING HOLE
CENTER:170mm
CENTER:170mm
TO THE LEFT
TO THE LEFT
d
e
A
A
a
170
60
Installation manual