1
WA L L M OU N T IN G
Install the programmable thermostat at
1,5 meters above the floor level, far from
kitchens, heat sources, windows and doors.
Make sure the base is fixed to a level surface,
without strains.
2
EL E CTR I C C ONNECT I O N S
Connect terminals 1 - 2 to the heating system
with two wires thus replacing the traditional
thermostat at any time and without adding
further connections. When the ambient
temperature increases, the relay will open
terminals 1 - 2 and will close terminals 1-4.
Terminal 4 is free and it may be used for
signalling or other purposes, as required.
3
O FF M ODE SE LECT I O N
When in OFF mode, Intellitherm may be set
to keep a fixed temperature of 5°C to protect
the system from the risk of freezing.
This selection must be carried out during
the installation and before inserting the
batteries.
Note: if this selection is needed to be
changed after the installation, Intellitherm
has to be reset and reprogrammed.
4
M O U N TI NG T HE T H E R M O STAT B O DY
O N TH E BA SE
5
I N S E R T IN G A N D R E P L AC IN G
T HE BATT E R IE S
Insert two long life AA 1,5V alkaline batteries,
paying attention to the indicated polarity.
Batteries last approximately 2 years: when
they begin to run down, the battery symbol
starts to flash on the display.
If the batteries are not replaced within 15
days, Intellitherm C55AX will switch-off
automatically and the display will indicate
OFF.
6
T IM E S ET T IN G
( s ee t h e p ic tu re on t h e r i g h t )
6
B 60 mm
A 83,5 mm
4 1 2
To set the ANTIFREEZE 5°C protection
move the dip switch HIGH.
To switch the system completely OFF,
move the dip switch DOWN.
Lift the cover and insert the batteries
-
1.5V
'AA'
Intellitherm
I N S T A L L A T I O N
loosen this screw and
turn the body of the
controller upwards to
detach the base for
fixing to the wall.
for flush-mounting
A
boxes (3 modules, 503)
B
for round
flush-mounting boxes
4 1 2
To be installed
!
b y q u a l i f i e d
personnel only!
+
-
+
1.5V
'AA'
time and day setting keys
e n g l i s h