DEVICE PROTECTION FEATURES
Dry running
Under-voltage on power line (activation at approx. 200 Volt)
Overvoltage on power line (activation at approx. 260 Volt)
Output terminal short circuit
Motor output current control
Internal overheating in inverter
Significant leakage with continuous motor pump restarts
INSTALLATION
HYDRAULIC CONNECTION:
The Sirio Entry must be installed on the pump delivery side, either upright or horizontally and respecting
the flow direction shown by the arrow on the cover. The pump outlet water flows through the device
before being distributed to the various appliances connected.
The water that enters the Sirio Entry unit must not contain any impurities and/or other substances that
could jam up the check valve fitted inside it. To reduce this risk as much as possible, it is advisable to fit
special filters on the intake side of the pump.
Install a small expansion tank (1-2 litres) after the Sirio Entry, to limit restarts caused by any small
leakages which are common in most systems. The pre-charge value of the tank must be suitable for the
pressure values set. This will also help to keep the operation constant in applications where water
requirements are greater (e.g. for dishwashers, toilet flushing systems, etc.).
On no account must a check valve be fitted between the Sirio Entry and the motor pump or between the
device itself and the user appliances, as it could cause device malfunctions.
A check valve can be fitted on the motor pump intake pipe, though, to prevent it draining when the pump
stops.
It is recommended that you do not install the equipment in shafts or watertight casing where heavy
condensation can form.
CAUTION: when the pump stops, the conduits are still pressured so a cock must be opened to bleed
the system before any work is carried out.
24