The sensor which detects the valve position is broken. Have the device checked by the manufacturer.
The pump is running at top speed but performance levels are low
The pump or the capacitor connection is not correct: check the electric wiring.
The pump is damaged or there is foreign matter clogging the waterway.
When more water is required of the system, the pressure drops
This is a normal condition which is due to the fact that the device is unable to force the pump above its
capacity curve. As a result, once a certain capacity is reached, the pressure is no longer offset as the pump
is already running at the highest number of revolutions allowed. In these cases, a pump with higher
performance levels should be installed.
T h e " I n v e r t e r e r r o r " m e s s a g e o f t e n a p p e a r s o n t h e d i s p l a y a f e w s e c o n d s a f t e r t h e m o t o r p u mp i s
started
The error may be caused by a non-compliant power voltage. With the pump running, use a suitable gauge
to measure the voltage at the power terminals and determine whether the problem concerns
underpowering or overpowering. If it is the former, use a power lead with a larger section to reduce
voltage drops, but if it is the latter, contact the manufacturer.
 MAINTENANCE:
The Sirio Entry is designed to keep maintenance requirements at a minimum. To guarantee the device a
long working life and perfect functionality, always follow the instructions below:
- ensure the device does not have to withstand temperatures of below 3° C; if this is not possible, make
s u r e a l l t h e w a t e r i n s i d e i t i s d r a i n e d o u t t o p r e v e n t i t f r o m f r e e z i n g u p a n d d a m a g i n g t h e d e v i c e ' s p l a s t i c
body;
- if the pump is equipped with intake filters, carry out regular checks to ensure they are clean;
- make sure the cover is always properly closed to prevent water leaking in from outside;
- switch off the power supply and drain the water from the system when it is going to be left unused for
some time;
- do not force the pump to run without intake water, as this could damage both the pump and the Sirio
Entry;
- before using the device with any other liquids than water, contact the manufacturer.
- do not carry out any operations when the device is open
- wait 3 minutes before removing the cover from the device so the condensers can discharge.