1) Check that the oil level is always over the dipstick mark (G).
2) Connect the high pressure hose to the outlet connection (A) tightening the
metal ring completely, and the other end to the automatic gun (D).
3) Fill the tank with fuel oil through opening (E) and detergent through
opening (F).
ATTENTION: When the diesel tank is filled up, check from the light "DIESEL
LEVEL" not to exceed the consented maximum level.
4) If the mains voltage corresponds (Volt/Hz ) to the indications on the label
fixed on the motor, you can plug the unit in (C).
It is prohibited to use extensions or loose plugs not to standards.
The electrical system the appliance is connected to must be made in
conformity with the laws in force in the country of installation.
It is recommended to have a differential thermomagnetic switch, with
sensitivity equal to 30 mA, upstream from the power socket.
5) Connect the water supply pipe (diameter not lower than 14 mm) to the
pump inlet connection (B).
Make sure that the suction filter of the suction hose connection is always
clean. The dirty filter causes a bad water supply and consequently a bad
pump operation with the inevitable risk of rapid wearing out and breakage
of internal mechanisms.
F
C
E
D
WARNING :
The earth connection is compulsory.
INSTALLATION
A
KH15010CP - KH16013CP
WARNING :
Diesel oil for vehicles only.
25
G
B