Starting And Stopping - Remington RM125 Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING:
Operate this unit only in a well-ventilated
outdoor area. Carbon monoxide exhaust fumes can be
lethal in a confined area.
WARNING:
Avoid accidentally starting the unit. To avoid
serious injury, the operator and the unit must be in a stable
position when pulling the starter rope (Fig. 5).
WARNING:
When starting the unit, make sure it is not
directed toward people, animals, windows, automobiles or
loose debris.
STARTING INSTRUCTIONS
1. Mix gasoline with oil. Refer to Oil and Fuel Mixing Instructions.
2. Fill the fuel tank. Refer to Fueling the Unit.
NOTE: There is no need to turn the unit on. The On/Off switch is in
the ON ( I ) position at all times (Fig. 3).
3. Slowly press and release the primer bulb 10 times (Fig. 4). If fuel
cannot be seen in the primer bulb, press and release the primer
bulb until fuel is visible.
4. Move the choke lever to the START position (Fig. 4).
5. Crouch in the starting position (Fig. 5).
NOTE: SQUEEZE and HOLD the throttle control for ALL further
steps (Fig. 3).
6. Squeeze and hold the throttle control (Fig. 3). Pull the starter
rope with a controlled and steady motion 5 times (Fig. 5).
7. Continue to squeeze the throttle control. Move the choke lever
to the WARM UP position (Fig. 4).
8. Continue to squeeze the throttle control. Pull the starter rope
with a controlled and steady motion 3 to 5 times to start the
engine.
9. Continue to squeeze the throttle control. Allow the engine to
warm up for 30 to 60 seconds.
10. Continue to squeeze the throttle control. Move the choke lever
to the RUN position (Fig. 4). Allow the engine to warm up for an
additional 60 seconds. The unit may be used during this time.
NOTE: The engine is properly warmed up when it accelerates
without hesitation.
IF... the engine hesitates, return the choke lever to the WARM UP
position and repeat steps 9 - 10.
IF... the engine does not start, begin the starting procedure with
step 3.
IF... the engine fails to start after a few attempts: Move the choke
lever to the RUN position. Squeeze and hold the throttle control.
Pull the starter rope with a controlled and steady motion 3 to 8
times. The engine should start. If it does not, repeat this
instruction.
IF... the engine is already warm, begin the starting procedure with
step 7.
STOPPING INSTRUCTIONS
1. Release the throttle control and allow the engine to idle.
2. Press and hold the On/Off switch in the OFF (O) position until
the engine comes to a complete stop (Fig. 3).

STARTING AND STOPPING

Choke Lever
Starter Rope Grip
9
Off (O)
On/Off Switch
Throttle Control
Fig. 3
Fig. 4
Fig. 5
On ( I )
Primer Bulb
Starting
Position

Publicidad