Installation and any transformation for using other types of gas, must be performed by qualified technicians according
to the law in force.
See technical data tables: 1.1.
WARNINGS:
Should the unit be installed against a wall, the latter must be heat
resistant to temperatures of 80°C and must be fireproof.
Before proceeding with the installation, remove the protective pla-
stic film from the relevant parts, eliminating any adhesive residues
with an appropriate cleaning product suitable for stainless steel.
Install the unit in a horizontal position; its correct levelling will
be achieved by rotating the adjustable feet.
If the unit is installed by itself, it is advisable to fasten it to make
its stability safer.
2.1

INFORMATION ABOUT GAS COOKTOPS

This manual applies to our Gas Cooktops, Type A
(Natural Gas and L.P.G.).
See table 1.1.
The label according to EN437 and EN203-1-2, is located:
a) on the Top units, at back or inside.
Example for Italy label: Category II 2H3÷
Pe= Incoming Pressure
Pi= Nozzle Pressure
2.2

LAWS, REGULATIONS AND TECHNICAL DIRECTIVES TO BE COMPLIED WITH

The following indications should be observed during installation:
- Accident and fire regulations in force
- Prescriptions by the Gas Supply Company, which should issue an authorisation before installation.
- Instructions for the "Installation of gas equipment"
- Instructions for the "Installation of electrical equipment"
- Prescriptions by the Electrical Supply Company
- Hygienic regulations.
2.3

INSTALLATION PLACE

- The unit should be installed in adequately ventilated places. (This unit requires a draft of at least 2cu.m/hr l kW T.C. (Ther-
mal Capacity).
- Install the equipment in compliance with the safety rules applicable in the country where the equipment is installed.
2.4

POSITIONING

- The various units may be installed individually or together with other units of our range.
- This unit is not suitable for encasing.
- The distance between side walls must be a minimum of 10cm; should the distance be less or the wall or floor material be
flammable, it is essential to use a thermal insulator.
2.5

MOUNTING THE TOP UNITS ON A BASE OR AN EXTENDING SUPPORT

All Top units are supplied with height-adjustable feet (P):
- When the unit is to be placed free on a table or a surface, tighten or loosen the feet (P) as shown in the illustration till it is
perfectly steady, then tighten the locknut (D) so that the foot is blocked. To prevent slipping, insert the rubber plugs (M)
into the feet's lower holes.
- When the unit is to be fixed to a base or an extending support, adjust the feet (P) till it is perfectly steady, then tighten the
locknut (D) so that the foot is blocked. Subsequently fasten from beneath by way of M5 screws (T) and respective washers,
screwing them into the feet as shown in the illustration.
2.6

GAS SYSTEM CONNECTION

- The unit should be supplied with gas having the characteristics and the pressure shown on Table II.
- The gas pressure is measured at the initial pressure outlet with the burner on (see Fig. 1)
- The unit is tested and fitted to operate with natural gas H G20 - 20mbar.
, Category II
1
- 15 -