GB
BAM 200-8-25 W
11
Safety valve
12
Pressure gauge (vessel pressure)
13
Pressure gauge (working pressure)
14
Electric motor
15
External protective motor switch
18
Filter pressure reducer
19
Quick-action coupling (clean, regu-
lated compressed air)
1.6
Maintenance
1.6.1 Cleaning the intake filter
1. Pull out the filter insert. (Fig. 5a)
2. Clean the filter insert using the blow gun,
exchange the filter insert if necessary.
3. Insert the filter insert.
1.7
Compressor inspections
This compressor is subject to a type approval
inspection. As a result, inspections by an au-
thorised expert prior to commissioning are
no longer necessary. The prototype identi-
fication code is located on the compressor
specification plate.
We recommend that a "qualified person" per-
form a pressure test on the vessel after 10
years, depending on general levels of wear
and tear.
A "qualified person" should be well informed
about Ordinance on Industrial Safety and
Health (formerly authorised expert)
Contact any of our approved service part-
ners. Most of our service partners have em-
ployees with expert qualifications.
The papers accompanying the vessel are
approval documents and must be kept
I/4
throughout the service life of the vessel.
These specifications only apply in Germa-
ny. Equivalent regulations apply in other
countries.
1.8
EC Declaration of Con-
formity
Compressor
BAM 200-8-25 W
Year of CE mark: 2008
We declare under sole responsibility that this
product complies with the following direc-
tives and standards:
98/37/EC (up to 28.12.2009); 2006/42/EC
(from 29.12.2009); 97/23/EC (module A);
87/404/EEC;
2000/14/EC;
2006/95/EC; DIN EN ISO 3744 / 12100; DIN
EN 1012 / 60204-1 / 55014-1 / 286-1, EN
61000-3-2, -3-3, -3-11.
pp Marco Lodni
Head of Development/Testing
08.2008
Schneider Druckluft GmbH
Ferdinand-Lassalle-Str. 43
72770 Reutlingen
Machine design: piston compressor
Sound power level L
ISO (RL 2000/14/EC):
Measured value: 92 dB(A),
Guaranteed value: 94 dB(A).
Nominated centre for the conformity evalua-
tion procedure: 0036
Serial no.
T100040
2004/108/EC;
according to DIN EN
WA