2 PRODUCT DESCRIPTION

This COMPACT® Electric heat exchanger is designed to accurately achieve the temperature
desired on your pool or spa. It is always aware of the actual water temperature and desired one
and reacts instantly thanks to it's new electronic control, far more accurate than electro-mechanic
ones.
The software that controls this unit is so powerful and accurate that even connects or disconnects
single heating elements depending on the actual heating needs at every single time, so when you
need to quickly heat the water, it will connect the full power of the unit, but once set point is
reached, the unit will automatically manage heating elements to connect or disconnect them
depending of heat demand.
You can see a detailed product parts overview on image 1.

3 INSTALLATION

This heater has many installation possibilities, but always respecting some guidelines.

3.1 POSITIONING

This heater can be installed on a horizontal surface or in a vertical one.
Holding claps are just to be rotated to the desired alignment. Remember, holding clamps are to
be screw fixed securely to a firm flat wall or base. See images 2.
WARNING
Remember leaving sufficient clear space around the unit to ease pipe connections
and servicing.
Unit can be positioned up to 20º angle respect to the vertical. See images 3.
When the unit is installed vertically, the water must always enter at the bottom. See images 4 and
6.

3.2 PIPING DETAILS

The heater is ready to connect to a 63mm (external diameter) pipe work, but adapters are
supplied to be able to connect to a 50mm (external diameter) piping system aswell.
The heater should be installed at a low point in the filtration system.
A check valve is recommended to prevent the heater from running out of water.
A by-pass is also recommended to ensure a correct water flow through the heater.
Heater must be installed after (downstream) the filter and before (upstream) chlorinator or
any other water treatment device.
ATTENTION
Heater must be installed after (downstream) the filter and before (upstream) any
water treatment device. Warranty void if not respected.
See image 5 and 6 for recommended installation.